Omitir enlaces
FLE-Q-F · PTFE/PFA Lined Electric Ball Valve

PTFE/PFA-Lined Electric Actuated Ball Valve

The FLE-Q-F PTFE/PFA-lined electric actuated ball valve is configured for automated isolation and selected control duties in corrosive process lines. Its fluoropolymer-lined flow path is designed to separate compatible process media from the metallic valve body, while the quarter-turn electric actuator supports remote on/off operation and selected regulating configurations. Final material and actuator selection depends on the actual medium and operating conditions.

PTFE / PFA Lining Conexión con bridas On/Off o modulante Corrosive Media Service
Email Our Engineers
inquiry@fleyendaflow.com
Reference Sizes
DN15–DN400*
Dimension Series
PN1.0 / 1.6 / 2.5 MPa*
Temperatura
De −20 °C a +180 °C*
Power
DC24V / AC110–380V
FLE-Q-F PTFE/PFA-lined electric actuated ball valve for corrosive chemical service
Corrosion-resistant automated flow control

PTFE or PFA lining provides a fluoropolymer barrier for compatible process media, while electric actuation enables remote operation of the valve assembly.

PTFE / PFAFluoropolymer lining options
0–90°Quarter-turn electric actuation
IP67 / IP68*Actuator protection options
Corrosion-resistant flow control

Why use a PTFE/PFA-lined electric ball valve?

In aggressive chemical service, lining selection is driven by the actual medium, concentration, temperature and pressure. PTFE and PFA provide a fluoropolymer barrier between the process fluid and the metal valve body.

The FLE-Q-F combines a lined ball valve with electric quarter-turn actuation for remote isolation and selected modulating duties. It is suited to applications where chemical resistance, dependable shutoff and automation are required in the same valve assembly.

  • ✓PTFE / PFA-lined wetted flow path for strong acids, alkalis and aggressive chemicals.
  • ✓Electric actuator options for on/off, regulating, feedback and intelligent control.
  • ✓ANSI, DIN and JIS flanged connection options for industrial piping systems.
  • ✓Carbon steel or stainless steel body configurations according to process duty.
Need a lining recommendation?Send the medium, concentration, temperature and pressure.
Email Engineering
Industrial process piping using automated lined electric ball valves
Automated process pipingRemote isolation and control for corrosive process lines.
Engineering data

Technical specifications

Core FLE-Q-F parameters for project selection. Final limits depend on valve size, lining material, media concentration, operating temperature and actuator torque.

Reference dimensional rangeDN15–DN400 for PN1.0 / PN1.6 MPa series; DN15–DN350 for PN2.5 MPa series, according to the supplied dimension schedule
Pressure / dimensional seriesReference dimensions are listed for PN1.0 MPa, PN1.6 MPa and PN2.5 MPa series. Confirm the actual pressure-temperature rating for the selected DN, lining and valve configuration.
Working temperature−20°C to +180°C, subject to lining and process conditions
Body materialCarbon Steel / Stainless Steel — WCB, CF8, CF8M
Lining materialPTFE or PFA
ConexiónFlanged connection; confirm ANSI, DIN, JIS or project-specific requirements against the supplied dimensional schedule and ordered configuration.
Applicable mediaStrong acids, alkalis, chlorine-containing media, corrosive gases, organic solvents and chemical wastewater
AccionamientoElectric quarter-turn actuator; on/off, regulating or intelligent configurations
Voltage optionsDC24V, AC24V, AC110V, AC220V, AC380V
Design referencesGB/T 12237, ISO 5211, ASME B16.34
TestingGB/T 13927, API 598
Fire-safe optionSelected API 607 / ISO 10497 compliant versions available
ProtecciónIP67 standard on selected actuators; IP68 optional
Explosion-proof optionSelected Ex d II BT4 / CT4 / CT6 Gb actuator configurations

*Confirm the final temperature, chemical compatibility and pressure rating for the actual media, concentration and operating cycle.

Send your operating conditions for valve sizing.Include size, pressure, temperature, medium, voltage and control mode.
Send Specifications by Email
Dimensions & engineering reference

FLE-Q-F Ball Valve Dimensions and Size Selection

Review the reference size schedule below to compare nominal size, face-to-face length, flange dimensions, bolt arrangement, overall height and weight. Confirm the required pressure series and connection standard before ordering.

Main connection dimensions and weight

Reference size schedule for preliminary selection

The table is transcribed from the dimensional data supplied for this product family. It is intended for initial size comparison and project evaluation; actual availability and final configuration must be confirmed with Fleyenda.

DN15–DN400*Reference range for PN1.0 / PN1.6 MPa
DN15–DN350*Reference range for PN2.5 MPa
mm / kgDimensions and weight units
Main connection dimensions and weight

DN Size Selection Table

Reference values transcribed from the supplied FLE-Q-F dimension chart. Dimensions are in millimeters; weight is in kilograms.

DN (mm)NPS (inch)LDD1D2fbZ–ØdD0HWeight (kg)
PN1.0 MPa
151/21409565452144–Ø14120802.5
203/414010575552164–Ø14140903
25115011585652164–Ø141601004.5
321 1/4165135100782184–Ø181601105.7
401 1/2180145110853184–Ø182001207
5022001601251003204–Ø182501359.5
652 1/22201801451203204–Ø1830014515
8032501951601353224/8–Ø1835018519
10042802151801553228–Ø1824019533
12553202452101853248–Ø1850021058
15063602802402103248–Ø23200*45093
20084003352952653268–Ø23240*490155
2501053339035032032812–Ø23240*550210
3001261044040036842812–Ø23320*600220
3501468650046042843016–Ø23320*675245
4001676256551548243216–Ø25360*780260
PN 1,6 MPa
151/21409565452144–Ø14120802.5
203/414010575552164–Ø14140903
25115011585652164–Ø141601004.5
321 1/4165135100782184–Ø181601105.7
401 1/2180145110853184–Ø182001207
5022001601251003204–Ø182501359.5
652 1/22201801451203204–Ø1830014515
8032501951601353228–Ø1835018519
10042802151801553248–Ø1824019533
12553202452101853268–Ø1850021058
15063602802402103288–Ø23200*45093
200840033529526533012–Ø23240*490155
2501053340535532033212–Ø25240*550210
3001261046041037543412–Ø25280*600220
3501468652047043543816–Ø25320*675245
4001676258052548544016–Ø30360*780260
PN2.5 MPa
151/21409565452164–Ø14120802.5
203/414010575552164–Ø14140903
25115011585652164–Ø141601004.5
321 1/4165135100782184–Ø181601105.7
401 1/2180145110853184–Ø182001207
5022001601251003204–Ø182501359.5
652 1/22201801451203228–Ø1830014515
8032501951601353228–Ø1830018519
10042802301901603248–Ø23200*19533
12553202702201883288–Ø25200*21058
15063603002502183308–Ø25200*45093
200840036031027833412–Ø25240*495155
2501053342537033233612–Ø30280*555210
3001261048543039044016–Ø30320*605230
3501468655049044844416–Ø34320*685250

Notes: (1) For PN1.0 MPa, DN80, the source chart indicates 4/8–Ø18; the accompanying note specifies Z = 4 for the JB78 bolt-hole arrangement and Z = 8 for other standards. (2) Asterisks shown beside selected D0 values are retained from the supplied chart; confirm their meaning with Fleyenda before final selection. (3) These are reference dimensions and weights. Final size availability, connection compatibility and pressure-temperature limits must be confirmed for the ordered configuration.

Need help confirming the correct valve size?Send the DN, pressure series, flange standard and operating conditions for a configuration review.
Confirm Valve Configuration
Lining selection

PTFE vs PFA: choose by process conditions

Both fluoropolymer linings provide broad chemical resistance. The correct choice depends on medium concentration, temperature, permeation risk, process cleanliness and operating cycle.

PTFE lining
PFA lining
Resistencia química
Broad resistance to many strong acids, alkalis and solvents.
Broad fluoropolymer resistance for demanding corrosive service.
Typical duty
General corrosive-fluid isolation where PTFE matches the process envelope.
Often considered where higher temperature or lower permeability is important.
Selection basis
Medium, concentration, temperature, pressure and cycling.
Medium, concentration, temperature, pressure and permeation requirement.
Recommended focus
Cost-effective lined automation for broad corrosive media service.
Often preferred when cleaner service, lower permeability or more demanding process duty is important.
Unsure whether PTFE or PFA is the better fit?Email the medium, concentration, temperature and pressure for a quick engineering review.
Ask an Engineer
Chemical compatibility

Designed for corrosive media handling

The FLE-Q-F is intended for process lines where an unlined metal flow path may be unsuitable because of aggressive chemical exposure.

Potential services include acid transfer, alkali handling, selected chlorine-related processes, pesticide and agrochemical production, wastewater neutralization, chemical dosing and solvent transfer. Compatibility must be checked against the exact chemical composition, concentration, temperature, pressure and phase.

Sulfuric acidCheck duty
Hydrochloric acidCheck duty
Hydrofluoric acidCheck duty
Phosphoric acidCheck duty
Alkalis / alkaline saltsCheck duty
Chlorine serviceCheck duty
Organic solventsCheck duty
Chemical wastewaterCheck duty
Chemical processing plant for PTFE PFA lined electric actuated ball valve applications
Procesamiento químicoCorrosive-media isolation, dosing, transfer and automated process control.
Electric actuator options

Actuator sizing based on valve duty and required control

The electric actuator should be selected from the actual valve torque, differential pressure, media characteristics, cycle frequency and required safety margin.

On / OffRemote open-close isolation for PLC, relay and equipment control.
ModulaciónSelected regulating and intelligent actuator configurations for position control.
Posición de falloSelected fail-open, fail-closed or no-reset configurations.
ComentariosSelected position feedback and passive contact switching options.
ProtecciónIP67, optional IP68 and selected explosion-proof configurations.
Manual OverrideHandwheel operation available on selected actuator configurations.
ActuadorStandard time / torqueOptional time / torquePeso
FLE-10525s / 50Nm4s / 20Nm; 10s / 30Nm2,2 kg
FLE-11025s / 100Nm15s / 50Nm5,1 kg
FLE-11625s / 160Nm15s / 80Nm5,1 kg
FLE-12025s / 200Nm15s / 100Nm7,5 kg
FLE-14025s / 400Nm15s / 200Nm7,5 kg
FLE-16025s / 600Nm15s / 300Nm8,1 kg
FLE-110050s / 1000Nm25s / 500Nm12,7 kg
FLE-120050s / 2000Nm25s / 1000Nm12,7 kg

Typical power supplies: DC24V, AC24V, AC110V, AC220V and AC380V depending on actuator configuration. Rotation range: 0–90° adjustable.

Need torque matching or control selection?Send valve size, differential pressure, voltage and control requirement.
Ask About Actuator Sizing
Chemical service selection

PTFE/PFA Lined Ball Valve Selection for Corrosive Fluids

Fluoropolymer lining selection must be based on the complete process envelope. The following matrix identifies the information to verify for common chemical services; it is not a blanket compatibility approval.

Process mediumTypical valve dutySelection checks before confirmation
Sulfuric acidAcid transfer, dosing and isolationConcentration, temperature, water content, pressure and exposure cycle
Hydrochloric acidAcid transfer and chemical dosingConcentration, temperature, gas phase or liquid phase, and permeation requirements
Hydrofluoric acidSpecialized corrosive-fluid serviceExact concentration, temperature, pressure and full wetted-component compatibility; engineering review required
Phosphoric acidProcess transfer and chemical productionConcentration, impurities, temperature and operating pressure
Caustic / alkaline solutionsAlkali handling and neutralizationConcentration, temperature, crystallization risk and seat/seal material
Chlorine-containing mediaChemical process isolationChlorine form, moisture content, phase, temperature and material compatibility of every wetted part
Organic solventsSolvent transfer and process isolationSolvent identity, mixture composition, temperature, permeation and seal compatibility
Chemical wastewaterWastewater collection, neutralization and transferActual chemical composition, suspended solids, temperature and valve cycling frequency

Chemical compatibility depends on the exact formulation and operating conditions. Confirm lining, seat, stem seal and other wetted materials as a complete assembly before specifying the valve.

Send your chemical name and concentration for a compatibility review.Include temperature, pressure, phase and any mixed or contaminated process media.
Request Compatibility Review
Application environments

Typical applications for PTFE/PFA-lined electric ball valves

These applications commonly require corrosion resistance together with automated shutoff or flow control. Final valve selection should always follow the real process conditions.

Industrial wastewater treatment application for PTFE PFA lined electric ball valves
Neutralization · Chemical DosingTratamiento de aguas residuales

Automated isolation and dosing in corrosive industrial wastewater and treatment chemical lines.

Pesticide and agrochemical manufacturing process equipment with corrosive chemical handling
Formulation · Transfer · DosingPesticide & Agrochemical Production

For aggressive raw materials, intermediates and process chemicals requiring lined flow paths.

Chemical processing plant piping for lined electric actuated ball valve service
Acids · Alkalis · SolventsProcesamiento químico

Corrosive media transfer, reactor isolation, utility lines and automated process control.

Pharmaceutical and fine chemical process piping for corrosion resistant lined valves
Fine Chemicals · Process ControlPharmaceutical & Fine Chemicals

Suitable where chemical resistance, repeatable actuation and controlled process handling are required.

Have a different application?Send your process medium and operating conditions for compatibility review.
Discuss Your Application
Selection guide

Specify the process first, then select the actuator

A reliable lined electric ball valve selection starts from chemical compatibility and process conditions, then moves to valve size, flange standard, torque and control requirements.

01

Identify the medium

Provide the chemical name, concentration, phase, solids content and any crystallization or polymerization risk.

02

Confirm temperature & pressure

Use the actual operating and design conditions, including vacuum, differential pressure and thermal cycling where relevant.

03

Select PTFE or PFA

Check chemical resistance, temperature capability, permeability and process cleanliness requirements.

04

Match size & flange

Confirm DN / inch size and ANSI, DIN, JIS or project-specific flange requirements.

05

Size actuator torque

Match valve torque under real service conditions and apply an appropriate engineering safety margin.

06

Define control & protection

Specify power supply, on/off or modulating control, feedback, fail position, IP rating and hazardous-area requirements.

Fastest way to get an accurate recommendation:Email the six items above with your project requirement.
Email Selection Data
Manufacturer & project support

PTFE/PFA Lined Electric Ball Valve Manufacturer for Industrial Projects

FLE-Q-F configurations combine a fluoropolymer-lined valve body with an electric actuator for corrosive-fluid isolation and automated process operation. Selection support focuses on the medium, concentration, pressure, temperature, nominal size, flange standard and control requirements.

For OEM equipment, chemical processing lines and engineering projects, valve body material, lining material, actuator torque, protection level and control mode should be reviewed together against the process conditions and ordered configuration.

API 598Valve inspection and testing reference
ISO 5211Quarter-turn actuator mounting interface
IP67 / 68*Selected actuator protection options
Project documentation

Technical information for project evaluation

Available documents and inspection records depend on the selected valve configuration and confirmed order requirements.

Material and lining detailsBody, lining, seat and sealing material details for the selected configuration.
Pressure test documentationApplicable inspection and test records according to the confirmed order requirements.
Actuator wiring informationPower supply, control wiring, feedback and limit-switch information for the selected actuator.
Operating and maintenance informationInstallation, commissioning and maintenance guidance for the supplied assembly.

Document scope and applicable standards are confirmed against the ordered valve model and project specification.

Frequently asked questions

PTFE/PFA-lined electric ball valve FAQs

Answers to common questions about lining selection, corrosive media, electric actuator control and project specification.

What is a PTFE/PFA-lined electric actuated ball valve?
It is a quarter-turn ball valve with PTFE or PFA lining on the process-contact surfaces and an electric actuator for automated operation. The lining isolates corrosive media from the metal valve body, while the actuator provides remote open-close or selected modulating control.
What is the difference between PTFE and PFA lining?
Both are fluoropolymers with broad chemical resistance. PTFE is widely used for corrosive service, while PFA is often considered where higher temperature capability, lower permeability or demanding process conditions are important. Final selection depends on the exact medium, concentration, temperature and pressure.
Can the valve be used for wastewater treatment and chemical dosing?
Yes, lined electric ball valves are commonly evaluated for corrosive wastewater, neutralization and chemical dosing lines. The lining and actuator configuration should be selected according to the treatment chemicals, concentration, temperature, pressure and cycle frequency.
Is the FLE-Q-F suitable for pesticide or agrochemical production?
It can be evaluated for pesticide and agrochemical processes involving corrosive raw materials, intermediates, acids, alkalis or solvents. Confirm compatibility for the exact formulation and process conditions before final selection.
Can this lined electric ball valve handle sulfuric or hydrochloric acid?
PTFE/PFA-lined valves are commonly evaluated for strong acid service, including sulfuric and hydrochloric acid applications. Suitability must be checked against concentration, temperature, pressure, phase and operating cycle.
Which electric actuator control options are available?
Depending on the selected actuator model, configurations can include on/off control, regulating or intelligent control, position feedback, manual override, selected fail-open / fail-closed functions and multiple AC or DC power supplies.
What nominal sizes are listed in the FLE-Q-F dimension table?
The supplied reference schedule lists DN15–DN400 for PN1.0 MPa and PN1.6 MPa dimensional series, and DN15–DN350 for the PN2.5 MPa series. Confirm the actual available valve size and pressure-temperature rating for the required configuration.
Are the dimensions in the table suitable for every flange standard?
No. The table reproduces the supplied reference dimension schedule. Flange drilling, face-to-face dimensions and installation interfaces must be checked against the required flange standard and the final ordered configuration.
How should I choose the valve size for a chemical pipeline?
Start with the required flow rate, pipeline size, process pressure, temperature and allowable pressure drop. Then verify the valve port and flow characteristics, lining compatibility, flange connection and actuator torque. The nominal pipeline DN alone is not enough to complete valve sizing.
What information is needed to select the correct valve?
Provide the process medium and concentration, operating and design temperature, pressure, valve size, flange standard, required body and lining material, actuator voltage, control signal, fail position and any IP or explosion-proof requirement.
Still have a technical question?Email inquiry@fleyendaflow.com and include your process conditions.
Email Fleyenda

Send your process conditions for an FLE-Q-F valve recommendation.

Medium, concentration, temperature, pressure, DN size, flange standard, power supply, control mode and fail-position requirement are the key selection inputs.

Email inquiry@fleyendaflow.com
Technical inquiry & quotation: inquiry@fleyendaflow.com