PTFE/PFA-Lined Electric Actuated Ball Valve
The FLE-Q-F PTFE/PFA-lined electric actuated ball valve is configured for automated isolation and selected control duties in corrosive process lines. Its fluoropolymer-lined flow path is designed to separate compatible process media from the metallic valve body, while the quarter-turn electric actuator supports remote on/off operation and selected regulating configurations. Final material and actuator selection depends on the actual medium and operating conditions.
- Reference Sizes
- DN15–DN400*
- Dimension Series
- PN1.0 / 1.6 / 2.5 MPa*
- Temperatura
- De −20 °C a +180 °C*
- Power
- DC24V / AC110–380V

PTFE or PFA lining provides a fluoropolymer barrier for compatible process media, while electric actuation enables remote operation of the valve assembly.
Why use a PTFE/PFA-lined electric ball valve?
In aggressive chemical service, lining selection is driven by the actual medium, concentration, temperature and pressure. PTFE and PFA provide a fluoropolymer barrier between the process fluid and the metal valve body.
The FLE-Q-F combines a lined ball valve with electric quarter-turn actuation for remote isolation and selected modulating duties. It is suited to applications where chemical resistance, dependable shutoff and automation are required in the same valve assembly.
- ✓PTFE / PFA-lined wetted flow path for strong acids, alkalis and aggressive chemicals.
- ✓Electric actuator options for on/off, regulating, feedback and intelligent control.
- ✓ANSI, DIN and JIS flanged connection options for industrial piping systems.
- ✓Carbon steel or stainless steel body configurations according to process duty.

Technical specifications
Core FLE-Q-F parameters for project selection. Final limits depend on valve size, lining material, media concentration, operating temperature and actuator torque.
| Reference dimensional range | DN15–DN400 for PN1.0 / PN1.6 MPa series; DN15–DN350 for PN2.5 MPa series, according to the supplied dimension schedule |
|---|---|
| Pressure / dimensional series | Reference dimensions are listed for PN1.0 MPa, PN1.6 MPa and PN2.5 MPa series. Confirm the actual pressure-temperature rating for the selected DN, lining and valve configuration. |
| Working temperature | −20°C to +180°C, subject to lining and process conditions |
| Body material | Carbon Steel / Stainless Steel — WCB, CF8, CF8M |
| Lining material | PTFE or PFA |
| Conexión | Flanged connection; confirm ANSI, DIN, JIS or project-specific requirements against the supplied dimensional schedule and ordered configuration. |
| Applicable media | Strong acids, alkalis, chlorine-containing media, corrosive gases, organic solvents and chemical wastewater |
| Accionamiento | Electric quarter-turn actuator; on/off, regulating or intelligent configurations |
| Voltage options | DC24V, AC24V, AC110V, AC220V, AC380V |
| Design references | GB/T 12237, ISO 5211, ASME B16.34 |
| Testing | GB/T 13927, API 598 |
| Fire-safe option | Selected API 607 / ISO 10497 compliant versions available |
| Protección | IP67 standard on selected actuators; IP68 optional |
| Explosion-proof option | Selected Ex d II BT4 / CT4 / CT6 Gb actuator configurations |
*Confirm the final temperature, chemical compatibility and pressure rating for the actual media, concentration and operating cycle.
FLE-Q-F Ball Valve Dimensions and Size Selection
Review the reference size schedule below to compare nominal size, face-to-face length, flange dimensions, bolt arrangement, overall height and weight. Confirm the required pressure series and connection standard before ordering.
Reference size schedule for preliminary selection
The table is transcribed from the dimensional data supplied for this product family. It is intended for initial size comparison and project evaluation; actual availability and final configuration must be confirmed with Fleyenda.
DN Size Selection Table
Reference values transcribed from the supplied FLE-Q-F dimension chart. Dimensions are in millimeters; weight is in kilograms.
| DN (mm) | NPS (inch) | L | D | D1 | D2 | f | b | Z–Ød | D0 | H | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PN1.0 MPa | |||||||||||
| 15 | 1/2 | 140 | 95 | 65 | 45 | 2 | 14 | 4–Ø14 | 120 | 80 | 2.5 |
| 20 | 3/4 | 140 | 105 | 75 | 55 | 2 | 16 | 4–Ø14 | 140 | 90 | 3 |
| 25 | 1 | 150 | 115 | 85 | 65 | 2 | 16 | 4–Ø14 | 160 | 100 | 4.5 |
| 32 | 1 1/4 | 165 | 135 | 100 | 78 | 2 | 18 | 4–Ø18 | 160 | 110 | 5.7 |
| 40 | 1 1/2 | 180 | 145 | 110 | 85 | 3 | 18 | 4–Ø18 | 200 | 120 | 7 |
| 50 | 2 | 200 | 160 | 125 | 100 | 3 | 20 | 4–Ø18 | 250 | 135 | 9.5 |
| 65 | 2 1/2 | 220 | 180 | 145 | 120 | 3 | 20 | 4–Ø18 | 300 | 145 | 15 |
| 80 | 3 | 250 | 195 | 160 | 135 | 3 | 22 | 4/8–Ø18 | 350 | 185 | 19 |
| 100 | 4 | 280 | 215 | 180 | 155 | 3 | 22 | 8–Ø18 | 240 | 195 | 33 |
| 125 | 5 | 320 | 245 | 210 | 185 | 3 | 24 | 8–Ø18 | 500 | 210 | 58 |
| 150 | 6 | 360 | 280 | 240 | 210 | 3 | 24 | 8–Ø23 | 200* | 450 | 93 |
| 200 | 8 | 400 | 335 | 295 | 265 | 3 | 26 | 8–Ø23 | 240* | 490 | 155 |
| 250 | 10 | 533 | 390 | 350 | 320 | 3 | 28 | 12–Ø23 | 240* | 550 | 210 |
| 300 | 12 | 610 | 440 | 400 | 368 | 4 | 28 | 12–Ø23 | 320* | 600 | 220 |
| 350 | 14 | 686 | 500 | 460 | 428 | 4 | 30 | 16–Ø23 | 320* | 675 | 245 |
| 400 | 16 | 762 | 565 | 515 | 482 | 4 | 32 | 16–Ø25 | 360* | 780 | 260 |
| PN 1,6 MPa | |||||||||||
| 15 | 1/2 | 140 | 95 | 65 | 45 | 2 | 14 | 4–Ø14 | 120 | 80 | 2.5 |
| 20 | 3/4 | 140 | 105 | 75 | 55 | 2 | 16 | 4–Ø14 | 140 | 90 | 3 |
| 25 | 1 | 150 | 115 | 85 | 65 | 2 | 16 | 4–Ø14 | 160 | 100 | 4.5 |
| 32 | 1 1/4 | 165 | 135 | 100 | 78 | 2 | 18 | 4–Ø18 | 160 | 110 | 5.7 |
| 40 | 1 1/2 | 180 | 145 | 110 | 85 | 3 | 18 | 4–Ø18 | 200 | 120 | 7 |
| 50 | 2 | 200 | 160 | 125 | 100 | 3 | 20 | 4–Ø18 | 250 | 135 | 9.5 |
| 65 | 2 1/2 | 220 | 180 | 145 | 120 | 3 | 20 | 4–Ø18 | 300 | 145 | 15 |
| 80 | 3 | 250 | 195 | 160 | 135 | 3 | 22 | 8–Ø18 | 350 | 185 | 19 |
| 100 | 4 | 280 | 215 | 180 | 155 | 3 | 24 | 8–Ø18 | 240 | 195 | 33 |
| 125 | 5 | 320 | 245 | 210 | 185 | 3 | 26 | 8–Ø18 | 500 | 210 | 58 |
| 150 | 6 | 360 | 280 | 240 | 210 | 3 | 28 | 8–Ø23 | 200* | 450 | 93 |
| 200 | 8 | 400 | 335 | 295 | 265 | 3 | 30 | 12–Ø23 | 240* | 490 | 155 |
| 250 | 10 | 533 | 405 | 355 | 320 | 3 | 32 | 12–Ø25 | 240* | 550 | 210 |
| 300 | 12 | 610 | 460 | 410 | 375 | 4 | 34 | 12–Ø25 | 280* | 600 | 220 |
| 350 | 14 | 686 | 520 | 470 | 435 | 4 | 38 | 16–Ø25 | 320* | 675 | 245 |
| 400 | 16 | 762 | 580 | 525 | 485 | 4 | 40 | 16–Ø30 | 360* | 780 | 260 |
| PN2.5 MPa | |||||||||||
| 15 | 1/2 | 140 | 95 | 65 | 45 | 2 | 16 | 4–Ø14 | 120 | 80 | 2.5 |
| 20 | 3/4 | 140 | 105 | 75 | 55 | 2 | 16 | 4–Ø14 | 140 | 90 | 3 |
| 25 | 1 | 150 | 115 | 85 | 65 | 2 | 16 | 4–Ø14 | 160 | 100 | 4.5 |
| 32 | 1 1/4 | 165 | 135 | 100 | 78 | 2 | 18 | 4–Ø18 | 160 | 110 | 5.7 |
| 40 | 1 1/2 | 180 | 145 | 110 | 85 | 3 | 18 | 4–Ø18 | 200 | 120 | 7 |
| 50 | 2 | 200 | 160 | 125 | 100 | 3 | 20 | 4–Ø18 | 250 | 135 | 9.5 |
| 65 | 2 1/2 | 220 | 180 | 145 | 120 | 3 | 22 | 8–Ø18 | 300 | 145 | 15 |
| 80 | 3 | 250 | 195 | 160 | 135 | 3 | 22 | 8–Ø18 | 300 | 185 | 19 |
| 100 | 4 | 280 | 230 | 190 | 160 | 3 | 24 | 8–Ø23 | 200* | 195 | 33 |
| 125 | 5 | 320 | 270 | 220 | 188 | 3 | 28 | 8–Ø25 | 200* | 210 | 58 |
| 150 | 6 | 360 | 300 | 250 | 218 | 3 | 30 | 8–Ø25 | 200* | 450 | 93 |
| 200 | 8 | 400 | 360 | 310 | 278 | 3 | 34 | 12–Ø25 | 240* | 495 | 155 |
| 250 | 10 | 533 | 425 | 370 | 332 | 3 | 36 | 12–Ø30 | 280* | 555 | 210 |
| 300 | 12 | 610 | 485 | 430 | 390 | 4 | 40 | 16–Ø30 | 320* | 605 | 230 |
| 350 | 14 | 686 | 550 | 490 | 448 | 4 | 44 | 16–Ø34 | 320* | 685 | 250 |
Notes: (1) For PN1.0 MPa, DN80, the source chart indicates 4/8–Ø18; the accompanying note specifies Z = 4 for the JB78 bolt-hole arrangement and Z = 8 for other standards. (2) Asterisks shown beside selected D0 values are retained from the supplied chart; confirm their meaning with Fleyenda before final selection. (3) These are reference dimensions and weights. Final size availability, connection compatibility and pressure-temperature limits must be confirmed for the ordered configuration.
PTFE vs PFA: choose by process conditions
Both fluoropolymer linings provide broad chemical resistance. The correct choice depends on medium concentration, temperature, permeation risk, process cleanliness and operating cycle.
Designed for corrosive media handling
The FLE-Q-F is intended for process lines where an unlined metal flow path may be unsuitable because of aggressive chemical exposure.
Potential services include acid transfer, alkali handling, selected chlorine-related processes, pesticide and agrochemical production, wastewater neutralization, chemical dosing and solvent transfer. Compatibility must be checked against the exact chemical composition, concentration, temperature, pressure and phase.

Actuator sizing based on valve duty and required control
The electric actuator should be selected from the actual valve torque, differential pressure, media characteristics, cycle frequency and required safety margin.
| Actuador | Standard time / torque | Optional time / torque | Peso |
|---|---|---|---|
| FLE-105 | 25s / 50Nm | 4s / 20Nm; 10s / 30Nm | 2,2 kg |
| FLE-110 | 25s / 100Nm | 15s / 50Nm | 5,1 kg |
| FLE-116 | 25s / 160Nm | 15s / 80Nm | 5,1 kg |
| FLE-120 | 25s / 200Nm | 15s / 100Nm | 7,5 kg |
| FLE-140 | 25s / 400Nm | 15s / 200Nm | 7,5 kg |
| FLE-160 | 25s / 600Nm | 15s / 300Nm | 8,1 kg |
| FLE-1100 | 50s / 1000Nm | 25s / 500Nm | 12,7 kg |
| FLE-1200 | 50s / 2000Nm | 25s / 1000Nm | 12,7 kg |
Typical power supplies: DC24V, AC24V, AC110V, AC220V and AC380V depending on actuator configuration. Rotation range: 0–90° adjustable.
PTFE/PFA Lined Ball Valve Selection for Corrosive Fluids
Fluoropolymer lining selection must be based on the complete process envelope. The following matrix identifies the information to verify for common chemical services; it is not a blanket compatibility approval.
| Process medium | Typical valve duty | Selection checks before confirmation |
|---|---|---|
| Sulfuric acid | Acid transfer, dosing and isolation | Concentration, temperature, water content, pressure and exposure cycle |
| Hydrochloric acid | Acid transfer and chemical dosing | Concentration, temperature, gas phase or liquid phase, and permeation requirements |
| Hydrofluoric acid | Specialized corrosive-fluid service | Exact concentration, temperature, pressure and full wetted-component compatibility; engineering review required |
| Phosphoric acid | Process transfer and chemical production | Concentration, impurities, temperature and operating pressure |
| Caustic / alkaline solutions | Alkali handling and neutralization | Concentration, temperature, crystallization risk and seat/seal material |
| Chlorine-containing media | Chemical process isolation | Chlorine form, moisture content, phase, temperature and material compatibility of every wetted part |
| Organic solvents | Solvent transfer and process isolation | Solvent identity, mixture composition, temperature, permeation and seal compatibility |
| Chemical wastewater | Wastewater collection, neutralization and transfer | Actual chemical composition, suspended solids, temperature and valve cycling frequency |
Chemical compatibility depends on the exact formulation and operating conditions. Confirm lining, seat, stem seal and other wetted materials as a complete assembly before specifying the valve.
Typical applications for PTFE/PFA-lined electric ball valves
These applications commonly require corrosion resistance together with automated shutoff or flow control. Final valve selection should always follow the real process conditions.

Automated isolation and dosing in corrosive industrial wastewater and treatment chemical lines.

For aggressive raw materials, intermediates and process chemicals requiring lined flow paths.

Corrosive media transfer, reactor isolation, utility lines and automated process control.

Suitable where chemical resistance, repeatable actuation and controlled process handling are required.
Specify the process first, then select the actuator
A reliable lined electric ball valve selection starts from chemical compatibility and process conditions, then moves to valve size, flange standard, torque and control requirements.
Identify the medium
Provide the chemical name, concentration, phase, solids content and any crystallization or polymerization risk.
Confirm temperature & pressure
Use the actual operating and design conditions, including vacuum, differential pressure and thermal cycling where relevant.
Select PTFE or PFA
Check chemical resistance, temperature capability, permeability and process cleanliness requirements.
Match size & flange
Confirm DN / inch size and ANSI, DIN, JIS or project-specific flange requirements.
Size actuator torque
Match valve torque under real service conditions and apply an appropriate engineering safety margin.
Define control & protection
Specify power supply, on/off or modulating control, feedback, fail position, IP rating and hazardous-area requirements.
PTFE/PFA Lined Electric Ball Valve Manufacturer for Industrial Projects
FLE-Q-F configurations combine a fluoropolymer-lined valve body with an electric actuator for corrosive-fluid isolation and automated process operation. Selection support focuses on the medium, concentration, pressure, temperature, nominal size, flange standard and control requirements.
For OEM equipment, chemical processing lines and engineering projects, valve body material, lining material, actuator torque, protection level and control mode should be reviewed together against the process conditions and ordered configuration.



Technical information for project evaluation
Available documents and inspection records depend on the selected valve configuration and confirmed order requirements.
Document scope and applicable standards are confirmed against the ordered valve model and project specification.
PTFE/PFA-lined electric ball valve FAQs
Answers to common questions about lining selection, corrosive media, electric actuator control and project specification.
What is a PTFE/PFA-lined electric actuated ball valve?
What is the difference between PTFE and PFA lining?
Can the valve be used for wastewater treatment and chemical dosing?
Is the FLE-Q-F suitable for pesticide or agrochemical production?
Can this lined electric ball valve handle sulfuric or hydrochloric acid?
Which electric actuator control options are available?
What nominal sizes are listed in the FLE-Q-F dimension table?
Are the dimensions in the table suitable for every flange standard?
How should I choose the valve size for a chemical pipeline?
What information is needed to select the correct valve?
Send your process conditions for an FLE-Q-F valve recommendation.
Medium, concentration, temperature, pressure, DN size, flange standard, power supply, control mode and fail-position requirement are the key selection inputs.