Bağlantıları atla
FLE-Q-F · Corrosive Media Flow Control

PTFE/PFA-Lined Electric Actuated Ball Valve

The FLE-Q-F fluoropolymer-lined electric ball valve is designed for automated isolation of corrosive process media. A PTFE or PFA lining separates the process fluid from the metallic valve body, helping protect wetted surfaces in chemical transfer, acid and alkali handling, and chemical wastewater systems. The electric quarter-turn actuator supports remote on/off operation and selected modulating control configurations.

DN15–DN300*Nominal size range
PN10–PN16*Pressure class
−20 to +180°C*Temperature range
PTFE / PFALining options
Technical enquiries: inquiry@fleyendaflow.com
FLE-Q-F PTFE PFA fluoropolymer lined electric actuated ball valve
Engineered for corrosive service

Protect the Flow Path from Aggressive Process Media

In corrosive-duty pipelines, the wetted material is a critical part of valve selection. FLE-Q-F uses a fluoropolymer-lined flow path to reduce direct contact between the process medium and the metallic pressure-containing body. PTFE and PFA lining options are selected according to the chemical medium and operating conditions.

01 / LINING PROTECTION

PTFE or PFA Lining

Fluoropolymer lining options provide broad chemical resistance for compatible acids, alkalis, solvents and corrosive wastewater. Select the grade against the actual chemical concentration and operating temperature.

02 / AUTOMATION

Electric Quarter-Turn Actuation

Remote 0–90° operation supports automated isolation from a PLC, relay panel or plant control system. On/off and selected regulating configurations are available.

03 / BODY OPTIONS

Metallic Pressure Body

Carbon steel or stainless-steel body options provide the structural base, while the fluoropolymer lining protects the wetted flow surfaces.

04 / SEALING

Corrosion-Service Seat System

PTFE-based seat and sealing options are selected to match the medium and temperature range, helping maintain shutoff performance in compatible service.

05 / CONTROL

Flexible Actuator Configuration

Voltage, control circuit, position feedback, manual override and selected fail-safe functions can be specified according to the automation requirements.

06 / INSTALLATION

Multiple Flange Standards

Flanged connection options can be configured to applicable GB, ANSI, DIN or JIS project requirements. Confirm facing, drilling and pressure class before ordering.

Lining material selection

PTFE vs PFA: Select the Lining for Your Process Conditions

Both PTFE and PFA are fluoropolymers used in corrosive-fluid service. Selection depends on chemical compatibility, operating temperature, pressure and the required service life.

  • PTFE lining: broad chemical resistance for many strong acids, alkalis and solvents.
  • PFA lining: considered for demanding corrosive duties where lining process, permeability and temperature requirements call for it.
  • Seat and seal compatibility: check all wetted components, not only the body lining.
  • Operating envelope: assess pressure and temperature together; do not assume the maximum values apply simultaneously.
  • Vacuum and cycling: confirm suitability for vacuum, thermal shock and frequent operating cycles.
Not sure which lining is suitable? Send your chemical and operating conditions.
Industrial chemical process equipment and piping
Technical data

FLE-Q-F Technical Specifications

Available configurations cover a range of sizes, pressure classes, lining materials and electric actuator options for corrosive-fluid service.

ParameterSpecification
ModelFLE-Q-F
Valve type2-way PTFE / PFA fluoropolymer-lined electric ball valve
Nominal sizeDN15–DN300 (½″–12″), subject to size and lining configuration
Working pressurePN10–PN16 (up to 1.6 MPa / 150 PSI), subject to size
Working temperature−20°C to +180°C, depending on lining, seat and medium
Body materialCarbon steel / stainless steel (WCB, CF8, CF8M)
Ball / wetted materialStainless steel grades and fluoropolymer-lined wetted surfaces, according to construction
Lining optionsPTFE / PFA; other fluoropolymer options subject to confirmation
Seat / sealing optionsPTFE, Nylon or PPL options according to configuration
BağlantıFlanged; ANSI, DIN, JIS or GB standard options
Applicable mediaCompatible acids, alkalis, chlorine-containing media, solvents and chemical wastewater
Actuator typeElectric quarter-turn actuator
Voltage optionsDC24V, AC24V, AC110V, AC220V, AC380V
Control optionsON/OFF, regulating, intelligent
Design referencesGB/T 12237, ISO 5211, ASME B16.34, as applicable
Testing referencesGB/T 13927 / API 598, according to product configuration
Actuator protectionIP67 standard configuration; IP68 optional
Explosion-proof optionSelected Ex d II BT4 / CT4 / CT6 Gb configurations
Fail-safe optionFail-open, fail-closed or no-reset, subject to actuator configuration
Need a size-specific rating or material confirmation? Request a technical review.

Electric Actuator Model and Torque Options

Quarter-turn · 0–90° adjustable
Actuator modelStandard time / torqueOptional time / torqueWeight
FLE-10525 s / 50 Nm4 s / 20 Nm; 10 s / 30 Nm2.2 kg
FLE-11025 s / 100 Nm15 s / 50 Nm5.1 kg
FLE-11625 s / 160 Nm15 s / 80 Nm5.1 kg
FLE-12025 s / 200 Nm15 s / 100 Nm7.5 kg
FLE-14025 s / 400 Nm15 s / 200 Nm7.5 kg
FLE-16025 s / 600 Nm15 s / 300 Nm8.1 kg
FLE-110050 s / 1000 Nm25 s / 500 Nm12.7 kg
FLE-120050 s / 2000 Nm25 s / 1000 Nm12.7 kg
Flanged connection dimensions

Flange Size and Installation Reference

Flange dimensions are provided for pipeline matching and installation planning. Flange drilling and pressure class are available according to the selected connection standard.

Need a certified dimensional drawing? Request the FLE-Q-F outline drawing.
FLE-Q-F PTFE lined electric ball valve flange outline drawing

Main Outline and Connecting Flange Size

Dimensions: mm
DNDN15DN20DN25DN32DN40DN50DN65DN80DN100DN125DN150DN200
Inch1/2″3/4″1″1-1/4″1-1/2″2″2-1/2″3″4″5″6″8″
D31520253040506580100125150200
D24555657885100120135155185210265
D1657585100110125145160180210240295
D95105115135145160180195215245280335
b141616181820202222242426
L140140150165180200220250280320360400
n–φd4–φ144–φ144–φ144–φ184–φ184–φ184–φ184/8–φ188–φ188–φ188–φ2312–φ23
Corrosive process applications

Automated Isolation for Chemical and Industrial Fluid Systems

FLE-Q-F is intended for process lines where the chemical resistance of the wetted flow path is a primary selection factor. Confirm chemical concentration, temperature, pressure and cleaning conditions before specifying the lining.

Acid & Alkali Transfer

Isolation in compatible acid, alkali and chemical dosing lines.

  • Sulfuric and phosphoric acid duties, subject to concentration and temperature review
  • Alkali and salt solutions
  • Corrosive chemical storage and transfer skids

Chlorine & Chemical Wastewater

Remote shutoff for selected chlorine-containing media and corrosive wastewater services.

  • Chlorine-related process lines, subject to compatibility review
  • Chemical wastewater collection and treatment
  • Corrosive process utility isolation
Typical industries

Applications of PTFE/PFA-Lined Electric Ball Valves

Fluoropolymer-lined valves are selected for compatible corrosive duties across chemical production, pharmaceutical processing, petrochemical operations and environmental treatment systems.

Chemical manufacturing plant process equipment

Chemical Manufacturing

Acid, alkali and corrosive reagent transfer.

Industrial pharmaceutical production facility

Pharmaceutical Processing

Compatible chemical and process utility lines.

Petrochemical industrial plant

Petrochemical Plants

Corrosive media isolation in process systems.

Wastewater treatment industrial facility

Chemical Wastewater

Automated isolation in corrosive treatment lines.

Engineering selection

Information Required for Correct Valve Selection

Fluoropolymer-lined valves need a process-specific review. Sharing the following information helps match the lining, pressure body, seat system and electric actuator to the application.

01 / CHEMICAL MEDIUM

Fluid name, concentration, impurities and compatibility requirements.

02 / OPERATING CONDITIONS

Normal and peak pressure, temperature, vacuum and cycling frequency.

03 / PIPELINE DETAILS

DN size, flange standard, pressure class, facing and installation orientation.

04 / ACTUATOR CONTROL

Voltage, on/off or modulating signal, feedback, fail position and hazardous-area needs.

Frequently asked questions

PTFE/PFA-Lined Electric Ball Valve FAQs

What is a PTFE-lined electric ball valve used for?

It is used for automated isolation of compatible corrosive fluids in chemical processing, acid and alkali transfer, petrochemical systems and chemical wastewater treatment. The fluoropolymer lining protects the wetted flow path from direct contact with the metallic body.

What is the difference between PTFE and PFA lining?

Both are fluoropolymers with broad chemical resistance. Their suitability differs according to temperature, lining process, permeation, mechanical requirements and the specific chemical. The choice should be based on the actual medium and operating envelope.

Can the FLE-Q-F valve handle sulfuric acid or hydrochloric acid?

Suitability depends on acid concentration, temperature, pressure and the selected lining and seat materials. Provide the chemical concentration and operating conditions for a compatibility review before ordering.

What pressure and temperature range is available?

The published product configuration lists PN10–PN16 and a temperature range up to +180°C, depending on lining, seat material, size and medium. These maximum values should not be assumed to apply simultaneously; confirm the size-specific rating.

What is the difference between a fluorine-lined and a standard stainless-steel ball valve?

A standard stainless-steel ball valve exposes its selected metal wetted surfaces to the process medium. A fluoropolymer-lined design adds a chemical-resistant lining between the medium and the metallic body, making it suitable for selected corrosive services where bare metal may not be compatible.

Can the electric actuator support modulating control?

Selected actuator configurations support regulating control, including compatible 4–20 mA or 0–10 V control circuits. Confirm the required signal, feedback, operating time and torque with the actuator configuration.

What information should I provide for a quotation?

Provide valve size, flange standard, medium and concentration, operating pressure and temperature, lining preference, actuator voltage, control mode, quantity and any hazardous-area requirement. A process datasheet or P&ID is useful for engineering review.

Need a Corrosion-Resistant Electric Ball Valve?

Send your chemical medium and operating conditions for FLE-Q-F configuration review.

Contact Fleyenda