QT-VQ-F2 Way Electric Actuator V Type Ball Valve
QT-VQ-F2 Way Electric Actuator V Type Ball Valve
The 2 Way Electric Actuator V Type Ball Valve uses a V-notch ball for precise linear flow control and tight shutoff, improving flow stability, reducing pressure loss, and extending service life, verified by API 598 and ISO 5211 testing for reliable industrial performance.
| Size Range | DN25–DN300 (1″–12″) | |||||
| Working Pressure Range: | PN10–PN40 / 150–300 PSI | |||||
| Working Temperature Range: | -20°C to +200°C | |||||
| Body Material: | Stainless Steel CF8 / CF8M, WCB, Duplex SS | |||||
| Connection Type: | Flanged (ANSI, DIN, JIS) | |||||
| Applicable Medium: | Water, Steam, Air, Oil, Gas, Slurry, Corrosive Chemicals | |||||
| Actuator Type: | Electric Rotary Actuator | |||||
| Voltage Options | AC220V, AC110V, AC380V, DC24V | |||||
| Design Standard | ISO 5211, ANSI B16.34, API 6D | |||||
| Testing Standard | API 598, EN 12266-1 | |||||
| Fire-Safe Design | API 607 Optional | |||||
| Certification | CE / ROHS / ISO / SIL / TUV /IP68 Waterproof | |||||
| Customization | Above Are Standard Parameter Samples. If You Have Specific Parameters And Materials, We Can Customize Them All. | |||||
| Actuator Model | Standard Time/Torque | Optional Time/Torque | Rotation Angle Range | Actuator Weight | Power Supply | Optional Control Circuit |
|---|---|---|---|---|---|---|
| FLE-105 | 25S/50Nm | 4S/20Nm 10S/30Nm | 0-90° Adjustable | 2.2kg |
DC24V AC24V AC110V AC220V AC380V |
A type B type C type D type E type F type |
| FLE-110 | 25S/100Nm | 15S/50Nm | 5.1kg | |||
| FLE-116 | 25S/160Nm | 15S/80Nm | 5.1kg | |||
| FLE-120 | 25S/200Nm | 15S/100Nm | 7.5kg | |||
| FLE-140 | 25S/400Nm | 15S/200Nm | 7.5kg | |||
| FLE-160 | 25S/600Nm | 15S/300Nm | 8.1kg | |||
| FLE-1100 | 50S/1000Nm | 25S/500Nm | 12.7kg | |||
| FLE-1200 | 50S/2000Nm | 25S/1000Nm | 12.7kg | |||
| Type | ON/OFF, Regulating, Intelligent | |||||
| Insulation Resistance | 100MΩ/500VDC | |||||
| Dielectric Strength | 1500V AC 1min. | |||||
| Level of Protection | IP67 (IP68 optional) | |||||
| Installed Location | 360° Installation at any Angle | |||||
| Electrical Interface | 2-G1/2 Metal Fitting, the corresponding metal cable joints should be installed according to the selected cables | |||||
| Ambient temperature | -20°C to +60°C | |||||
| Optional Explosion Proof | Ex d II BT4 / CT4 / CT6 Gb | |||||
| Power-loss reset (fail-safe) function | Fail-open, Fail-closed or No-reset (factory-selectable) | |||||
| Optional functions | Overtorque protection, dehumidification heater, passive contact switch, operating handwheel | |||||
Certified Quality for Industrial Valve Applications
Fleyenda valves and electric actuators are built for stable performance, reliable operation, and long-term industrial use. With certified quality support, they are suitable for water treatment, chemical processing, automation, and industrial process control systems.
FAQs That 80% Users Interest
1. What are the main advantages of using a 2 Way Electric Actuator V Type Ball Valve for flow control?
• The electric V-port valve offers precise linear flow regulation with stable pressure and smooth operation.
• The V-shaped ball minimizes pressure loss and enhances throttling accuracy.
• Tight-sealing seats ensure zero leakage and reliable shutoff.
• Easily integrates with automation systems for efficient process control.
2. How can I choose the right actuator for a V Type Electric Control Valve?
• Match actuator torque with valve size, pressure, and medium.
• Select proper signal type—on/off or modulating control—based on system needs.
• Ensure ISO 5211 mounting compatibility between actuator and valve.
• Choose suitable voltage and protection level for the operating environment.
3. Where does a 2 Way Motorized V Port Ball Valve perform better than standard types?
• The V-notch design provides a self-cleaning effect for slurry or viscous media.
• Delivers wider control range and smoother flow than globe or butterfly valves.
• Reduces actuation torque for faster, energy-efficient operation.
• Performs well in HVAC, chemical, and water-treatment process control.
4. What maintenance ensures the long-term reliability of a V Type Electric Regulating Valve?
• Regularly check actuator torque and calibration accuracy.
• Inspect seats and seals for wear under high-pressure or corrosive service.
• Test feedback and limit switches for correct positioning.
• Keep actuator housings sealed and verify manual override functionality.