تخطي الروابط

F-ZJHN Pneumatic Double-seat Control Valve

F-ZJHN Pneumatic Double-seat Control Valve

The Double-Seat Control Valve features a balanced dual-plug design that reduces actuator force and pressure imbalance, ensuring precise flow control under high differential pressure, improving stability and service life in steam, chemical, and gas systems, verified by IEC 60534 and API 598 leakage tests ≤ 0.01 % Cv.

Size RangeDN25 – DN400 (1″ – 16″)
Working Pressure Range:PN16 – PN100 / Class 150 – 600 (1.6 – 10 MPa)
Working Temperature Range:−40 °C to +450 °C
Body Material:WCB, CF8, CF8M, CF3M, Alloy Steel
Connection Type:Flanged (ASME B16.5 / GB/T 9113), Welded
Applicable Medium:Steam, Gas, Oil, Water, Corrosive Liquids
Actuator Type:Pneumatic Diaphragm, Electric
Voltage OptionsAC 220 V, AC 110 V, DC 24 V
Design StandardIEC 60534, GB/T 4213, ANSI B16.34
Testing StandardISO 5208, API 598, GB/T 13927
Fire-Safe DesignAPI 607, ISO 10497 (Optional)
CertificationCE / RoHS / ISO 9001 / IP65 (Actuator)
CustomizationAbove Are Standard Parameter Samples. If You Have Specific Parameters And Materials, We Can Customize Them All.

SeriesATAWLinearPneumatic Cylinderالصحية
Valve BodyBall valve, butterfly valve, plug valveGate valve, Global valveKnife gate valveSanitary butterfly valve
FunctionDouble Acting, Single Acting (Failure Resetting FO or FC)
ملحقات التحكم • Solenoid Valve, Filter Regulator Lubricator (F.R.L.), Positioner, Limit Switch, Handwheel
• Solenoid Valve & Positioner are with Explosion-proof grade and Signal Feedback type for choice
Operating Medium Clean and dry or lubricated air or inert gas. Any non-corrosive gas that is compatible with the internal parts of the actuator and the lubricant.
The dew point temperature of the operating medium is -20°C, and the size of impurity particles is no more than 30u.
When selecting a positioner, the impurity particle size should be no more than 5u.
Air Source Pressure3bar to 8bar
Operating Environment Temperature • Standard type: -20°C to +80°C
• Low-temperature type: -40°C to +80°C
• High-temperature type: -20°C to +160°C
Lubrication Under normal operating conditions, the standard type does not require additional lubricant.
For low-temperature or high-temperature environments, special lubricants are required.
Quality Assurance

Certified Quality for Industrial Valve Applications

Fleyenda valves and electric actuators are built for stable performance, reliable operation, and long-term industrial use. With certified quality support, they are suitable for water treatment, chemical processing, automation, and industrial process control systems.

FAQs That 80% Users Interest

• The Double-Seat Control Valve uses a balanced dual-plug design for stable flow control under large pressure differentials.
• It minimizes vibration and hunting in automated process systems.
• High Cv capacity ensures precise adjustment in steam, gas, and chemical pipelines.
• Proper actuator tuning maintains reliable flow regulation without oscillation.

• The balanced design of this industrial control valve reduces actuator force but limits sealing tightness.
• Dual plugs may not fully close both seats, allowing slight internal leakage.
• For zero-leakage applications, a single-seat globe valve is preferred.
• The double-plug configuration is designed for modulation, not isolation.

• Use anti-cavitation or low-noise trims to control energy within the flow-control valve.
• Keep pressure drop within safe limits to reduce erosion in liquid or steam service.
• Add diffusers or restrictors to manage turbulence in process pipelines.
• Choose durable valve materials to resist cavitation wear.

• Match actuator size and signal range to the valve design for smooth modulation.
• Calibrate positioners for accurate flow response in DCS or PLC control.
• Confirm signal compatibility with 4–20 mA, HART, or digital systems.
• Ensure the valve-actuator assembly supports required flow range and response speed.

يستخدم هذا الموقع ملفات تعريف الارتباط لتحسين تجربتك في تصفح الويب.