{"id":9506,"date":"2025-08-30T09:24:44","date_gmt":"2025-08-30T09:24:44","guid":{"rendered":"https:\/\/www.fleyendavalve.com\/?post_type=product&#038;p=9506"},"modified":"2026-04-09T07:12:06","modified_gmt":"2026-04-09T07:12:06","slug":"pneumatic-carbon-steel-fluorine-lining-ball-valve","status":"publish","type":"product","link":"https:\/\/www.fleyendavalve.com\/pt\/product\/pneumatic-actuated-valve\/pneumatic-actuator-ball-valve\/pneumatic-carbon-steel-fluorine-lining-ball-valve\/","title":{"rendered":"V\u00e1lvula de esfera pneum\u00e1tica FAT-Q-F de a\u00e7o carbono com revestimento de fl\u00faor"},"content":{"rendered":"<table style=\"border-collapse: collapse; width: 573.02pt;\" border=\"0\" width=\"764\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et5\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Faixa de tamanhos<\/td>\n<td class=\"et6\" style=\"width: 369.35pt;\" width=\"492\">DN15\u2013DN300 (1\/2&#8243;\u201312&#8243;)<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Faixa de press\u00e3o de trabalho:<\/td>\n<td class=\"et6\">PN10\u2013PN16 (10\u201316 bar)<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Faixa de temperatura de opera\u00e7\u00e3o:<\/td>\n<td class=\"et6\">\u221220\u00b0C to +180\u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Material do corpo:<\/td>\n<td class=\"et6\">Carbon Steel (WCB) with PTFE\/PFA Lining<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Tipo de conex\u00e3o:<\/td>\n<td class=\"et6\">Flanged Ends (DIN, ANSI, JIS)<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Meio aplic\u00e1vel:<\/td>\n<td class=\"et6\">Acid, Alkali, Salt, Corrosive Chemicals<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Tipo de atuador:<\/td>\n<td class=\"et6\">Pneumatic Actuator (Double-Acting\/Spring-Return)<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Op\u00e7\u00f5es de tens\u00e3o<\/td>\n<td class=\"et6\">24V DC, 110V AC, 220V AC<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Padr\u00e3o de projeto<\/td>\n<td class=\"et6\">GB\/T 12237, ISO 5211, API 608<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Norma de ensaio<\/td>\n<td class=\"et6\">GB\/T 13927, API 598<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et7\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Projeto \u00e0 prova de fogo<\/td>\n<td class=\"et6\">Optional<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et8\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Certifica\u00e7\u00e3o<\/td>\n<td class=\"et4\">CE \/ RoHS \/ ISO 9001 \/ IP65 (atuador)<\/td>\n<\/tr>\n<tr style=\"height: 35.00pt;\">\n<td class=\"et8\" style=\"height: 35.00pt; width: 204.35pt;\" width=\"272\" height=\"46\">Personaliza\u00e7\u00e3o<\/td>\n<td class=\"et10\" style=\"width: 369.35pt;\" width=\"492\">Acima est\u00e3o exemplos de par\u00e2metros padr\u00e3o. Se voc\u00ea tiver par\u00e2metros e materiais espec\u00edficos, podemos personalizar todos eles.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"8\" style=\"border-collapse: collapse; width: 100%; text-align: center;\">\n<thead>\n<tr>\n<th>S\u00e9rie<\/th>\n<th>AT<\/th>\n<th>AW<\/th>\n<th>Linear<\/th>\n<th>Cilindro pneum\u00e1tico<\/th>\n<th>Sanit\u00e1rio<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Corpo da v\u00e1lvula<\/td>\n<td colspan=\"2\">V\u00e1lvula de esfera, v\u00e1lvula borboleta, v\u00e1lvula de obturador<\/td>\n<td>V\u00e1lvula de guilhotina, V\u00e1lvula Global<\/td>\n<td>V\u00e1lvula de guilhotina<\/td>\n<td>V\u00e1lvula borboleta sanit\u00e1ria<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"5\">Dupla a\u00e7\u00e3o, a\u00e7\u00e3o simples (FO ou FC com reajuste em caso de falha)<\/td>\n<\/tr>\n<tr>\n<td>Acess\u00f3rios de controle<\/td>\n<td colspan=\"5\" style=\"text-align:left;\">\n        \u2022 V\u00e1lvula solen\u00f3ide, filtro-regulador-lubrificador (F.R.L.), posicionador, interruptor de fim de curso, volante<br \/>\n        \u2022 A v\u00e1lvula solen\u00f3ide e o posicionador s\u00e3o do tipo \u00e0 prova de explos\u00e3o e com retorno de sinal, \u00e0 escolha\n      <\/td>\n<\/tr>\n<p>    <!-- \u56fe\u4e8c\u5185\u5bb9\u5f00\u59cb --><\/p>\n<tr>\n<td>Meio de opera\u00e7\u00e3o<\/td>\n<td colspan=\"5\" style=\"text-align:left;\">\n        Ar limpo e seco ou lubrificado, ou g\u00e1s inerte. Qualquer g\u00e1s n\u00e3o corrosivo que seja compat\u00edvel com as pe\u00e7as internas do atuador e com o lubrificante.<br \/>\n        A temperatura do ponto de orvalho do meio de opera\u00e7\u00e3o \u00e9 de -20 \u00b0C, e o tamanho das part\u00edculas de impurezas n\u00e3o ultrapassa 30 u.<br \/>\n        Ao selecionar um posicionador, o tamanho das part\u00edculas de impureza n\u00e3o deve ser superior a 5u.\n      <\/td>\n<\/tr>\n<tr>\n<td>Press\u00e3o da fonte de ar<\/td>\n<td colspan=\"5\">3 bar a 8 bar<\/td>\n<\/tr>\n<tr>\n<td>Temperatura do ambiente de opera\u00e7\u00e3o<\/td>\n<td colspan=\"5\" style=\"text-align:left;\">\n        \u2022 Tipo padr\u00e3o: -20 \u00b0C a +80 \u00b0C<br \/>\n        \u2022 Tipo para baixas temperaturas: -40 \u00b0C a +80 \u00b0C<br \/>\n        \u2022 Tipo para altas temperaturas: -20 \u00b0C a +160 \u00b0C\n      <\/td>\n<\/tr>\n<tr>\n<td>Lubrifica\u00e7\u00e3o<\/td>\n<td colspan=\"5\" style=\"text-align:left;\">\n        Em condi\u00e7\u00f5es normais de opera\u00e7\u00e3o, o modelo padr\u00e3o n\u00e3o requer lubrificante adicional.<br \/>\n        Para ambientes de baixa ou alta temperatura, s\u00e3o necess\u00e1rios lubrificantes especiais.\n      <\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>The Pneumatic Carbon Steel Fluorine Lining Ball Valve with PTFE\/PFA lining offers strong acid and alkali resistance, ensuring reliable sealing and long service life in corrosive pipelines, verified by API 598 and GB 13927 pressure tests for proven durability and stability.<\/p>","protected":false},"featured_media":9509,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[40],"product_tag":[],"class_list":{"0":"post-9506","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-pneumatic-actuator-ball-valve","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/product\/9506","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/media\/9509"}],"wp:attachment":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/media?parent=9506"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/product_brand?post=9506"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/product_cat?post=9506"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/product_tag?post=9506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}