{"id":11307,"date":"2026-07-23T09:30:25","date_gmt":"2026-07-23T09:30:25","guid":{"rendered":"https:\/\/www.fleyendavalve.com\/?page_id=11307"},"modified":"2026-07-23T10:18:41","modified_gmt":"2026-07-23T10:18:41","slug":"linear-electric-actuator-control-valve","status":"publish","type":"page","link":"https:\/\/www.fleyendavalve.com\/pt\/linear-electric-actuator-control-valve\/","title":{"rendered":"Linear Electric Actuator Control Valve"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"11307\" class=\"elementor elementor-11307\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0534838 e-flex e-con-boxed wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no wpr-column-slider-no wpr-equal-height-no e-con e-parent\" data-id=\"0534838\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28edb9b e-con-full e-flex wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no wpr-column-slider-no wpr-equal-height-no e-con e-parent\" data-id=\"28edb9b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2753d2e elementor-widget elementor-widget-html\" data-id=\"2753d2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<!doctype html>\r\n<html lang=\"en\">\r\n<head>\r\n  <meta charset=\"utf-8\">\r\n  <meta name=\"viewport\" content=\"width=device-width, initial-scale=1\">\r\n\r\n  <!-- Keep the HTML and CSS files in the same directory. -->\r\n  <link rel=\"stylesheet\" href=\"linear_electric_actuator_control_valve_product_page.css?v=20260723-1\">\r\n<\/head>\r\n\r\n<body class=\"leacv-body\">\r\n  <main class=\"leacv-page\">\r\n\r\n    <!-- HERO -->\r\n    <section class=\"leacv-hero\">\r\n      <div class=\"leacv-container leacv-hero-grid\">\r\n        <div class=\"leacv-hero-copy\">\r\n          <p class=\"leacv-eyebrow\">Industrial Linear Motion Control<\/p>\r\n          <h1>Linear Electric Actuator Control Valve<\/h1>\r\n\r\n          <p class=\"leacv-lead\">\r\n            A linear electric actuator control valve package designed for accurate valve-stem\r\n            positioning, dependable modulating service and automated process control in HVAC,\r\n            water treatment, power, chemical and general industrial systems.\r\n          <\/p>\r\n\r\n          <p class=\"leacv-keyword-line\">\r\n            Related solutions:\r\n            <strong>Linear Electric Actuator<\/strong>,\r\n            <strong>Electric Linear Actuator Control Valve<\/strong>,\r\n            <strong>Modulating Control Valve<\/strong>,\r\n            <strong>Electric Actuated Globe Valve<\/strong>,\r\n            <strong>Linear Valve Actuator<\/strong> and\r\n            <strong>381LS Electric Actuator<\/strong>.\r\n          <\/p>\r\n\r\n          <div class=\"leacv-hero-actions\">\r\n            <a class=\"leacv-btn leacv-btn--primary\" href=\"mailto:inquiry@fleyendaflow.com\">\r\n              Request a Quote\r\n            <\/a>\r\n            <a class=\"leacv-btn leacv-btn--secondary\" href=\"#leacv-models\">\r\n              View Model Data\r\n            <\/a>\r\n          <\/div>\r\n\r\n          <div class=\"leacv-hero-facts\" aria-label=\"Key product data\">\r\n            <div class=\"leacv-hero-fact\">\r\n              <b>800\u201326,000 N<\/b>\r\n              <span>Available thrust range<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-hero-fact\">\r\n              <b>30 \/ 60 \/ 100 mm<\/b>\r\n              <span>Maximum stroke options<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-hero-fact\">\r\n              <b>4\u201320 mA or 1\u20135 V<\/b>\r\n              <span>Input signal options<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-hero-fact\">\r\n              <b>\u00b11% Accuracy<\/b>\r\n              <span>Reference control accuracy<\/span>\r\n            <\/div>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"leacv-product-visual\">\r\n          <!-- Replace with a transparent-background product package image. -->\r\n          <img decoding=\"async\"\r\n            src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-7.webp\"\r\n            alt=\"Linear Electric Actuator Control Valve\"\r\n          >\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- HORIZONTAL ANCHOR NAV -->\r\n    <nav class=\"leacv-section-nav\" aria-label=\"Product page sections\">\r\n      <div class=\"leacv-container leacv-section-nav-inner\">\r\n        <a href=\"#leacv-overview\">Overview<\/a>\r\n        <a href=\"#leacv-advantages\">Vantagens<\/a>\r\n        <a href=\"#leacv-technical\">Technical Data<\/a>\r\n        <a href=\"#leacv-models\">Model Selection<\/a>\r\n        <a href=\"#leacv-drawings\">Drawings<\/a>\r\n        <a href=\"#leacv-dimensions\">Dimensions<\/a>\r\n        <a href=\"#leacv-brackets\">Mounting Brackets<\/a>\r\n        <a href=\"#leacv-applications\">Applications<\/a>\r\n        <a href=\"#leacv-selection\">Guia de Sele\u00e7\u00e3o<\/a>\r\n      <\/div>\r\n    <\/nav>\r\n\r\n    <!-- OVERVIEW -->\r\n    <section class=\"leacv-section\" id=\"leacv-overview\">\r\n      <div class=\"leacv-container leacv-overview-grid\">\r\n        <figure class=\"leacv-media\">\r\n          <!-- Replace with a product detail or installation image. -->\r\n          <img decoding=\"async\"\r\n            src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-10.webp\"\r\n            alt=\"Electric linear actuator mounted on an industrial control valve\"\r\n          >\r\n          <figcaption>\r\n            Linear electric actuation for precise control-valve stem positioning\r\n          <\/figcaption>\r\n        <\/figure>\r\n\r\n        <div>\r\n          <p class=\"leacv-eyebrow\">Product Overview<\/p>\r\n          <h2>Accurate Linear Positioning for Automated Control Valves<\/h2>\r\n\r\n          <p class=\"leacv-lead\">\r\n            The 381LS series linear electric actuator converts an electrical command signal\r\n            into controlled linear stem travel. It can be combined with globe valves and other\r\n            compatible regulating valves through a selected mounting bracket and stem connection.\r\n          <\/p>\r\n\r\n          <ul class=\"leacv-key-points\">\r\n            <li>\r\n              <span>01<\/span>\r\n              <div>\r\n                <strong>Closed-loop modulating control:<\/strong>\r\n                accepts standard process signals and provides position feedback for automation systems.\r\n              <\/div>\r\n            <\/li>\r\n            <li>\r\n              <span>02<\/span>\r\n              <div>\r\n                <strong>Wide thrust coverage:<\/strong>\r\n                models range from 800 N to 26,000 N for different valve sizes and shutoff loads.\r\n              <\/div>\r\n            <\/li>\r\n            <li>\r\n              <span>03<\/span>\r\n              <div>\r\n                <strong>Flexible stroke adjustment:<\/strong>\r\n                zero point and operating stroke can be adjusted to match the connected valve.\r\n              <\/div>\r\n            <\/li>\r\n            <li>\r\n              <span>04<\/span>\r\n              <div>\r\n                <strong>Valve package compatibility:<\/strong>\r\n                multiple bracket codes support a range of common control-valve diameters.\r\n              <\/div>\r\n            <\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- ADVANTAGES -->\r\n    <section class=\"leacv-section leacv-section--soft\" id=\"leacv-advantages\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Product Advantages<\/p>\r\n        <h2>Why Choose a Linear Electric Actuator Control Valve<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          The actuator package is configured around required thrust, speed, stroke, valve size,\r\n          control signal and installation environment.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-advantages\">\r\n          <article class=\"leacv-advantage-row\">\r\n            <div class=\"leacv-number\">01<\/div>\r\n            <h3>Precision Modulating Control<\/h3>\r\n            <p>\r\n              Reference basic error, hysteresis and dead zone are each controlled within\r\n              the specified catalog limits for repeatable valve positioning.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-advantage-row\">\r\n            <div class=\"leacv-number\">02<\/div>\r\n            <h3>Multiple Thrust and Stroke Options<\/h3>\r\n            <p>\r\n              Eight catalog models cover 800 N to 26,000 N with 30 mm, 60 mm or 100 mm\r\n              maximum travel options.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-advantage-row\">\r\n            <div class=\"leacv-number\">03<\/div>\r\n            <h3>Standard Automation Signals<\/h3>\r\n            <p>\r\n              Supports DC 4\u201320 mA or DC 1\u20135 V command signals and DC 4\u201320 mA output feedback.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-advantage-row\">\r\n            <div class=\"leacv-number\">04<\/div>\r\n            <h3>Broad Power-Supply Compatibility<\/h3>\r\n            <p>\r\n              AC and DC power options are available for different regions, control panels\r\n              and industrial electrical standards.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-advantage-row\">\r\n            <div class=\"leacv-number\">05<\/div>\r\n            <h3>Configurable Mounting Brackets<\/h3>\r\n            <p>\r\n              Bracket codes A-2 through C-6 support multiple valve diameter ranges and\r\n              stem-thread arrangements.\r\n            <\/p>\r\n          <\/article>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- TECHNICAL DATA -->\r\n    <section class=\"leacv-section\" id=\"leacv-technical\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Main Technical Parameters<\/p>\r\n        <h2>Electrical, Signal and Control Specifications<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          The following values are translated from the supplied actuator manual and should\r\n          be confirmed for the final ordered model.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-technical-layout\">\r\n          <div class=\"leacv-technical-column\">\r\n            <div class=\"leacv-technical-heading\">\r\n              <span>01<\/span>\r\n              <h3>Power Supply and Consumption<\/h3>\r\n            <\/div>\r\n\r\n            <dl class=\"leacv-spec-table\">\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Single-Phase AC<\/dt>\r\n                <dd>AC 110 V 50\/60 Hz; AC 220 V 50\/60 Hz; AC 240 V 60 Hz<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Three-Phase AC<\/dt>\r\n                <dd>AC 380 V 50 Hz<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>DC Supply<\/dt>\r\n                <dd>DC 24 V, DC 36 V, DC 48 V<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Type A Consumption<\/dt>\r\n                <dd>50 VA at rated load<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Type B Consumption<\/dt>\r\n                <dd>150 VA at rated load<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Type C Consumption<\/dt>\r\n                <dd>220 VA at rated load<\/dd>\r\n              <\/div>\r\n            <\/dl>\r\n          <\/div>\r\n\r\n          <div class=\"leacv-technical-column\">\r\n            <div class=\"leacv-technical-heading\">\r\n              <span>02<\/span>\r\n              <h3>Signals, Accuracy and Stroke<\/h3>\r\n            <\/div>\r\n\r\n            <dl class=\"leacv-spec-table\">\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Input Signal<\/dt>\r\n                <dd>DC 4\u201320 mA or DC 1\u20135 V<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Output Signal<\/dt>\r\n                <dd>DC 4\u201320 mA, load resistance \u2264 500 \u03a9<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Basic Error<\/dt>\r\n                <dd>\u00b11%<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Hysteresis<\/dt>\r\n                <dd>\u2264 1%<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Dead Zone<\/dt>\r\n                <dd>\u2264 1%<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Zero Adjustment<\/dt>\r\n                <dd>\u00b125%<\/dd>\r\n              <\/div>\r\n              <div class=\"leacv-spec-line\">\r\n                <dt>Stroke Adjustment<\/dt>\r\n                <dd>20%\u2013100%<\/dd>\r\n              <\/div>\r\n            <\/dl>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"leacv-alert\">\r\n          <strong>Power-supply notes:<\/strong>\r\n          Type C models have higher power consumption and are not offered with nominal\r\n          DC 24 V, DC 36 V or DC 48 V supply. Supply-voltage deviation should remain\r\n          within \u00b110%. Specify rated voltage and frequency when ordering.\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- WIRING & ENVIRONMENT -->\r\n    <section class=\"leacv-section leacv-section--soft\">\r\n      <div class=\"leacv-container leacv-dual-section\">\r\n        <div>\r\n          <p class=\"leacv-eyebrow\">External Wiring<\/p>\r\n          <h2>Recommended Cable Arrangement<\/h2>\r\n          <p class=\"leacv-lead\">\r\n            Use shielded cable for input and output signals. Do not route the power conductors\r\n            and signal conductors in the same cable.\r\n          <\/p>\r\n\r\n          <div class=\"leacv-table-wrap\">\r\n            <table class=\"leacv-data-table leacv-compact-table\">\r\n              <thead>\r\n                <tr>\r\n                  <th>Item<\/th>\r\n                  <th>Standard S-Type Actuator<\/th>\r\n                <\/tr>\r\n              <\/thead>\r\n              <tbody>\r\n                <tr><th>Power Cable<\/th><td>3-core, 1.5 mm\u00b2<\/td><\/tr>\r\n                <tr><th>Signal Cable<\/th><td>4-core, 1.5 mm\u00b2<\/td><\/tr>\r\n                <tr><th>Cable Entry<\/th><td>2 \u00d7 M20 \u00d7 1.5<\/td><\/tr>\r\n              <\/tbody>\r\n            <\/table>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div>\r\n          <p class=\"leacv-eyebrow\">Environmental Conditions<\/p>\r\n          <h2>Reference Operating Environment<\/h2>\r\n          <p class=\"leacv-lead\">\r\n            Confirm enclosure, heater and site conditions before selecting the actuator package.\r\n          <\/p>\r\n\r\n          <div class=\"leacv-table-wrap\">\r\n            <table class=\"leacv-data-table leacv-compact-table\">\r\n              <thead>\r\n                <tr>\r\n                  <th>Condition<\/th>\r\n                  <th>Standard S-Type Actuator<\/th>\r\n                <\/tr>\r\n              <\/thead>\r\n              <tbody>\r\n                <tr><th>Temperature, No Heater<\/th><td>-10\u00b0C to 60\u00b0C<\/td><\/tr>\r\n                <tr><th>Temperature, With Heater<\/th><td>-35\u00b0C to 60\u00b0C<\/td><\/tr>\r\n                <tr><th>Relative Humidity<\/th><td>\u2264 95%<\/td><\/tr>\r\n                <tr><th>Ambient Gas<\/th><td>Non-corrosive gas<\/td><\/tr>\r\n                <tr><th>Mechanical Vibration<\/th><td>\u2264 1.5 g<\/td><\/tr>\r\n              <\/tbody>\r\n            <\/table>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- MODEL TABLE -->\r\n    <section class=\"leacv-section\" id=\"leacv-models\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Series Selection<\/p>\r\n        <h2>381LS Linear Electric Actuator Model Range<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          Select the actuator according to required thrust, operating speed, valve travel\r\n          and shutoff force.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-table-wrap\">\r\n          <table class=\"leacv-data-table\">\r\n            <thead>\r\n              <tr>\r\n                <th>Model<\/th>\r\n                <th>Output Thrust (N)<\/th>\r\n                <th>Operating Speed (mm\/s)<\/th>\r\n                <th>Maximum Stroke (mm)<\/th>\r\n              <\/tr>\r\n            <\/thead>\r\n            <tbody>\r\n              <tr><th>381LSA-08<\/th><td>800<\/td><td>4.2<\/td><td>30<\/td><\/tr>\r\n              <tr><th>381LSA-20<\/th><td>2,000<\/td><td>2.1<\/td><td>30<\/td><\/tr>\r\n              <tr><th>381LSB-30<\/th><td>3,000<\/td><td>3.5<\/td><td>60<\/td><\/tr>\r\n              <tr><th>381LSB-50<\/th><td>5,000<\/td><td>1.7<\/td><td>60<\/td><\/tr>\r\n              <tr><th>381LSC-65<\/th><td>6,500<\/td><td>2.8<\/td><td>100<\/td><\/tr>\r\n              <tr><th>381LSC-99<\/th><td>10,000<\/td><td>2.0<\/td><td>100<\/td><\/tr>\r\n              <tr><th>381LSC-160<\/th><td>16,000<\/td><td>1.0<\/td><td>100<\/td><\/tr>\r\n              <tr><th>381LSC-260<\/th><td>26,000<\/td><td>1.0<\/td><td>100<\/td><\/tr>\r\n            <\/tbody>\r\n          <\/table>\r\n        <\/div>\r\n\r\n        <p class=\"leacv-note\">\r\n          Verify that actuator thrust is sufficient for valve shutoff differential pressure,\r\n          packing friction and required safety margin.\r\n        <\/p>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- TWO DRAWING PANELS -->\r\n    <section class=\"leacv-section leacv-section--soft\" id=\"leacv-drawings\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Actuator Drawings<\/p>\r\n        <h2>381LSA \/ 381LSB and 381LSC Outline Views<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          Two drawing panels are retained to separate the A\/B actuator body from the larger\r\n          C-series configuration. Replace the URLs with final English engineering drawings.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-drawing-grid\">\r\n          <figure class=\"leacv-drawing-panel\">\r\n            <div class=\"leacv-drawing-label\">\r\n              <span>01<\/span>\r\n              <strong>381LSA \/ 381LSB Outline Drawing<\/strong>\r\n            <\/div>\r\n            <div class=\"leacv-drawing-image\">\r\n              <!-- Replace with the first actuator drawing URL. -->\r\n              <img decoding=\"async\"\r\n                src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-8.webp\"\r\n                alt=\"381LSA and 381LSB linear electric actuator outline drawing\"\r\n              >\r\n            <\/div>\r\n          <\/figure>\r\n\r\n          <figure class=\"leacv-drawing-panel\">\r\n            <div class=\"leacv-drawing-label\">\r\n              <span>02<\/span>\r\n              <strong>381LSC Outline Drawing<\/strong>\r\n            <\/div>\r\n            <div class=\"leacv-drawing-image\">\r\n              <!-- Replace with the second actuator drawing URL. -->\r\n              <img decoding=\"async\"\r\n                src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-9.webp\"\r\n                alt=\"381LSC linear electric actuator outline drawing\"\r\n              >\r\n            <\/div>\r\n          <\/figure>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- ACTUATOR DIMENSIONS -->\r\n    <section class=\"leacv-section\" id=\"leacv-dimensions\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Overall Dimensions<\/p>\r\n        <h2>381LS Actuator Dimension Reference<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          Dimension symbols correspond to the actuator outline drawings. Values are in\r\n          millimetres unless otherwise stated.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-table-wrap\">\r\n          <table class=\"leacv-data-table leacv-wide-table\">\r\n            <thead>\r\n              <tr>\r\n                <th>Model<\/th>\r\n                <th>D1<\/th>\r\n                <th>D2<\/th>\r\n                <th>H1<\/th>\r\n                <th>h1<\/th>\r\n                <th>h2<\/th>\r\n                <th>d1<\/th>\r\n                <th>d2<\/th>\r\n                <th>d3<\/th>\r\n                <th>C<\/th>\r\n                <th>K<\/th>\r\n                <th>M<\/th>\r\n                <th>W<\/th>\r\n                <th>Y<\/th>\r\n                <th>O<\/th>\r\n                <th>F<\/th>\r\n                <th>R<\/th>\r\n                <th>X<\/th>\r\n                <th>Weight (kg)<\/th>\r\n              <\/tr>\r\n            <\/thead>\r\n            <tbody>\r\n              <tr>\r\n                <th>381LSA<\/th><td>\u00d8225<\/td><td>\u00d8260<\/td><td>200<\/td><td>78<\/td><td>18<\/td>\r\n                <td>\u00d890<\/td><td>\u00d870<\/td><td>\u00d855<\/td><td>M14 \u00d7 1.5<\/td><td>15<\/td><td>M8<\/td>\r\n                <td>28<\/td><td>87<\/td><td>10<\/td><td>12<\/td><td>80<\/td><td>75<\/td><td>12<\/td>\r\n              <\/tr>\r\n              <tr>\r\n                <th>381LSB<\/th><td>\u00d8255<\/td><td>\u00d8290<\/td><td>280<\/td><td>125<\/td><td>31<\/td>\r\n                <td>\u00d8125<\/td><td>\u00d8102<\/td><td>\u00d870<\/td><td>M18 \u00d7 1.5<\/td><td>18<\/td><td>M10<\/td>\r\n                <td>45<\/td><td>90<\/td><td>10<\/td><td>15<\/td><td>100<\/td><td>91<\/td><td>22<\/td>\r\n              <\/tr>\r\n              <tr>\r\n                <th>381LSC<\/th><td>\u00d8310<\/td><td>\u00d8360<\/td><td>415<\/td><td>175<\/td><td>31<\/td>\r\n                <td>\u00d8150<\/td><td>\u00d8125<\/td><td>\u00d885<\/td><td>M22 \u00d7 1.5<\/td><td>24<\/td><td>M12<\/td>\r\n                <td>\u2014<\/td><td>90<\/td><td>10<\/td><td>15<\/td><td>160<\/td><td>120<\/td><td>55<\/td>\r\n              <\/tr>\r\n            <\/tbody>\r\n          <\/table>\r\n        <\/div>\r\n\r\n        <p class=\"leacv-note\">\r\n          Dimension W is not specified for the 381LSC row in the supplied catalog image.\r\n          Confirm the final approved production drawing before manufacturing the mounting structure.\r\n        <\/p>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- BRACKETS -->\r\n    <section class=\"leacv-section leacv-section--soft\" id=\"leacv-brackets\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Mounting Brackets<\/p>\r\n        <h2>Actuator-to-Control-Valve Bracket Selection<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          Each actuator model may be paired with two or three bracket sizes according to\r\n          the connected control-valve diameter. Always verify actuator thrust against valve\r\n          opening and closing force.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-bracket-layout\">\r\n          <div>\r\n            <h3>Model and Valve Diameter Compatibility<\/h3>\r\n            <div class=\"leacv-table-wrap\">\r\n              <table class=\"leacv-data-table leacv-bracket-table\">\r\n                <thead>\r\n                  <tr>\r\n                    <th>Actuator Model<\/th>\r\n                    <th>Control Valve Diameter (DN)<\/th>\r\n                    <th>Bracket Code<\/th>\r\n                  <\/tr>\r\n                <\/thead>\r\n                <tbody>\r\n                  <tr><th>381LSA-08<\/th><td>20<\/td><td>A-2<\/td><\/tr>\r\n                  <tr><th>381LSA-20<\/th><td>20\u201350<\/td><td>A-2<\/td><\/tr>\r\n                  <tr><th>381LSB-30<\/th><td>25\u201350<\/td><td>B-3<\/td><\/tr>\r\n                  <tr><th>381LSB-30<\/th><td>65\u2013100<\/td><td>B-4<\/td><\/tr>\r\n                  <tr><th>381LSB-50<\/th><td>25\u201350<\/td><td>B-3<\/td><\/tr>\r\n                  <tr><th>381LSB-50<\/th><td>65\u2013100<\/td><td>B-4<\/td><\/tr>\r\n                  <tr><th>381LSB-50<\/th><td>125\u2013150<\/td><td>B-5<\/td><\/tr>\r\n                  <tr><th>381LSC-65<\/th><td>65\u2013100<\/td><td>C-4<\/td><\/tr>\r\n                  <tr><th>381LSC-65<\/th><td>125\u2013200<\/td><td>C-5<\/td><\/tr>\r\n                  <tr><th>381LSC-99<\/th><td>125\u2013200<\/td><td>C-5<\/td><\/tr>\r\n                  <tr><th>381LSC-99<\/th><td>250\u2013300<\/td><td>C-6<\/td><\/tr>\r\n                  <tr><th>381LSC-160<\/th><td>125\u2013200<\/td><td>C-5<\/td><\/tr>\r\n                  <tr><th>381LSC-260<\/th><td>125\u2013200<\/td><td>C-5<\/td><\/tr>\r\n                  <tr><th>381LSC-400<\/th><td>250\u2013300<\/td><td>C-6<\/td><\/tr>\r\n                <\/tbody>\r\n              <\/table>\r\n            <\/div>\r\n          <\/div>\r\n\r\n          <figure class=\"leacv-bracket-drawing\">\r\n            <!-- Replace with the bracket and valve connection drawing URL. -->\r\n            <img decoding=\"async\"\r\n              src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-11.webp\"\r\n              alt=\"Linear electric actuator mounting bracket and valve connection drawing\"\r\n            >\r\n            <figcaption>\r\n              Reference bracket and valve connection arrangement\r\n            <\/figcaption>\r\n          <\/figure>\r\n        <\/div>\r\n\r\n        <div class=\"leacv-subsection\">\r\n          <h3>Bracket Connection Dimensions<\/h3>\r\n          <div class=\"leacv-table-wrap\">\r\n            <table class=\"leacv-data-table\">\r\n              <thead>\r\n                <tr>\r\n                  <th>Bracket Code<\/th>\r\n                  <th>L<\/th>\r\n                  <th>L1<\/th>\r\n                  <th>D<\/th>\r\n                  <th>n-d1<\/th>\r\n                  <th>D2<\/th>\r\n                  <th>H<\/th>\r\n                  <th>D3<\/th>\r\n                  <th>L2<\/th>\r\n                <\/tr>\r\n              <\/thead>\r\n              <tbody>\r\n                <tr><th>A-2<\/th><td>173<\/td><td>78<\/td><td>\u00d880<\/td><td>4-\u00d810<\/td><td>\u00d860<\/td><td>130<\/td><td>100<\/td><td>17<\/td><\/tr>\r\n                <tr><th>B-3<\/th><td>215<\/td><td>125<\/td><td>\u00d880<\/td><td>4-\u00d810<\/td><td>\u00d860<\/td><td>157<\/td><td>125<\/td><td>21<\/td><\/tr>\r\n                <tr><th>B-4<\/th><td>255<\/td><td>125<\/td><td>\u00d8105<\/td><td>4-\u00d812<\/td><td>\u00d880<\/td><td>175<\/td><td>135<\/td><td>21<\/td><\/tr>\r\n                <tr><th>B-5<\/th><td>267<\/td><td>125<\/td><td>\u00d8118<\/td><td>4-\u00d814<\/td><td>\u00d895<\/td><td>177<\/td><td>155<\/td><td>25<\/td><\/tr>\r\n                <tr><th>C-4<\/th><td>285<\/td><td>175<\/td><td>\u00d8105<\/td><td>4-\u00d812<\/td><td>\u00d880<\/td><td>205<\/td><td>155<\/td><td>27<\/td><\/tr>\r\n                <tr><th>C-5<\/th><td>310<\/td><td>175<\/td><td>\u00d8118<\/td><td>4-\u00d814<\/td><td>\u00d895<\/td><td>210<\/td><td>155<\/td><td>27<\/td><\/tr>\r\n                <tr><th>C-6<\/th><td>345<\/td><td>175<\/td><td>\u00d8130<\/td><td>4-\u00d818<\/td><td>\u00d8100<\/td><td>220<\/td><td>175<\/td><td>27<\/td><\/tr>\r\n              <\/tbody>\r\n            <\/table>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <div class=\"leacv-subsection\">\r\n          <h3>Reference Control-Valve Stem Connection<\/h3>\r\n          <div class=\"leacv-table-wrap\">\r\n            <table class=\"leacv-data-table leacv-compact-reference\">\r\n              <thead>\r\n                <tr>\r\n                  <th>Control Valve Diameter (DN)<\/th>\r\n                  <th>Reference L<\/th>\r\n                  <th>Valve Stem Thread<\/th>\r\n                <\/tr>\r\n              <\/thead>\r\n              <tbody>\r\n                <tr><th>20, 25, 32, 40, 50<\/th><td>95<\/td><td>M8<\/td><\/tr>\r\n                <tr><th>65, 80, 100<\/th><td>135<\/td><td>M12 \u00d7 1.25<\/td><\/tr>\r\n                <tr><th>125, 150, 200<\/th><td>140<\/td><td>M16 \u00d7 1.5<\/td><\/tr>\r\n                <tr><th>250, 300<\/th><td>170<\/td><td>M20 \u00d7 1.5<\/td><\/tr>\r\n              <\/tbody>\r\n            <\/table>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- APPLICATIONS -->\r\n    <section class=\"leacv-section\" id=\"leacv-applications\">\r\n      <div class=\"leacv-container leacv-application-layout\">\r\n        <div>\r\n          <p class=\"leacv-eyebrow\">Aplica\u00e7\u00f5es t\u00edpicas<\/p>\r\n          <h2>Industrial Applications for Linear Actuator Control Valves<\/h2>\r\n          <p class=\"leacv-lead\">\r\n            The package is suitable for automated flow, pressure, temperature and level control\r\n            where controlled linear valve travel is required.\r\n          <\/p>\r\n\r\n          <div class=\"leacv-application-list\">\r\n            <div class=\"leacv-application-item\">\r\n              <strong>HVAC and Building Automation<\/strong>\r\n              <span>Hot-water, chilled-water and thermal-energy control loops.<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-application-item\">\r\n              <strong>Tratamento de \u00c1gua<\/strong>\r\n              <span>Flow, pressure and level regulation in treatment and distribution systems.<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-application-item\">\r\n              <strong>Power and Energy<\/strong>\r\n              <span>Steam, condensate, cooling and auxiliary process regulation.<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-application-item\">\r\n              <strong>Processamento Qu\u00edmico<\/strong>\r\n              <span>Compatible process-media control with suitable valve body and trim materials.<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-application-item\">\r\n              <strong>Industrial Utilities<\/strong>\r\n              <span>Plant air, water, heat-transfer and general utility systems.<\/span>\r\n            <\/div>\r\n            <div class=\"leacv-application-item\">\r\n              <strong>Automated Equipment Skids<\/strong>\r\n              <span>PLC-controlled packages requiring repeatable linear valve positioning.<\/span>\r\n            <\/div>\r\n          <\/div>\r\n        <\/div>\r\n\r\n        <figure class=\"leacv-application-image\">\r\n          <!-- Replace with one clean application or installation image. -->\r\n          <img decoding=\"async\"\r\n            src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2025\/06\/PowerNuclear_MainImage.jpg\"\r\n            alt=\"Linear electric actuator control valve application\"\r\n          >\r\n        <\/figure>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- SELECTION GUIDE -->\r\n    <section class=\"leacv-section leacv-section--soft\" id=\"leacv-selection\">\r\n      <div class=\"leacv-container\">\r\n        <p class=\"leacv-eyebrow\">Guia de Sele\u00e7\u00e3o<\/p>\r\n        <h2>How to Configure the Correct Linear Actuator Package<\/h2>\r\n        <p class=\"leacv-lead leacv-copy-limit\">\r\n          Match actuator thrust, travel and speed to the connected valve and process-control requirements.\r\n        <\/p>\r\n\r\n        <div class=\"leacv-selection-table\">\r\n          <article class=\"leacv-selection-row\">\r\n            <small>Valve Load<\/small>\r\n            <h3>Required Thrust and Safety Margin<\/h3>\r\n            <p>\r\n              Confirm differential pressure, valve unbalance force, packing friction and shutoff requirement.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-selection-row\">\r\n            <small>Travel<\/small>\r\n            <h3>30 mm, 60 mm or 100 mm Stroke<\/h3>\r\n            <p>\r\n              Match maximum actuator travel to the connected valve stem movement and adjustment range.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-selection-row\">\r\n            <small>Control<\/small>\r\n            <h3>Input Signal and Position Feedback<\/h3>\r\n            <p>\r\n              Confirm DC 4\u201320 mA or DC 1\u20135 V command signal and required output feedback.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-selection-row\">\r\n            <small>Electrical<\/small>\r\n            <h3>Voltage, Frequency and Consumption<\/h3>\r\n            <p>\r\n              Select the correct AC or DC supply and confirm the power requirements of actuator type A, B or C.\r\n            <\/p>\r\n          <\/article>\r\n\r\n          <article class=\"leacv-selection-row\">\r\n            <small>Mechanical<\/small>\r\n            <h3>Bracket and Stem Connection<\/h3>\r\n            <p>\r\n              Confirm actuator model, valve diameter, bracket code, stem thread and installation dimensions.\r\n            <\/p>\r\n          <\/article>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- ORDERING -->\r\n    <section class=\"leacv-section\">\r\n      <div class=\"leacv-container leacv-order-guide\">\r\n        <div>\r\n          <p class=\"leacv-eyebrow\">Ordering Information<\/p>\r\n          <h2>Details Required for Actuator and Valve Selection<\/h2>\r\n          <p class=\"leacv-lead\">\r\n            Complete operating and mechanical data helps determine the correct actuator,\r\n            bracket, stem connector and control package.\r\n          <\/p>\r\n        <\/div>\r\n\r\n        <div class=\"leacv-order-steps\">\r\n          <div class=\"leacv-order-step\">\r\n            <div>\r\n              <strong>Control valve type and nominal diameter<\/strong>\r\n              <span>State the valve style, DN size, pressure class and connection standard.<\/span>\r\n            <\/div>\r\n          <\/div>\r\n          <div class=\"leacv-order-step\">\r\n            <div>\r\n              <strong>Required thrust and valve travel<\/strong>\r\n              <span>Provide calculated operating force, shutoff force and full stem stroke.<\/span>\r\n            <\/div>\r\n          <\/div>\r\n          <div class=\"leacv-order-step\">\r\n            <div>\r\n              <strong>Power supply and signal<\/strong>\r\n              <span>Confirm voltage, frequency, input command and position-feedback requirements.<\/span>\r\n            <\/div>\r\n          <\/div>\r\n          <div class=\"leacv-order-step\">\r\n            <div>\r\n              <strong>Bracket and stem connection<\/strong>\r\n              <span>Provide valve top dimensions, stem thread and preferred mounting arrangement.<\/span>\r\n            <\/div>\r\n          <\/div>\r\n          <div class=\"leacv-order-step\">\r\n            <div>\r\n              <strong>Installation environment<\/strong>\r\n              <span>State temperature, humidity, vibration and any heater or enclosure requirements.<\/span>\r\n            <\/div>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/section>\r\n\r\n    <!-- CTA -->\r\n    <section class=\"leacv-cta\">\r\n      <div class=\"leacv-container leacv-cta-inner\">\r\n        <div>\r\n          <h2>Configure Your Linear Electric Actuator Control Valve<\/h2>\r\n          <p>\r\n            Send the valve size, required thrust, stroke, supply voltage, control signal,\r\n            mounting dimensions and operating conditions for a suitable quotation and drawing.\r\n          <\/p>\r\n        <\/div>\r\n        <a class=\"leacv-btn leacv-btn--light\" href=\"mailto:inquiry@fleyendaflow.com\">\r\n          Request a Quote\r\n        <\/a>\r\n      <\/div>\r\n    <\/section>\r\n\r\n  <\/main>\r\n<\/body>\r\n<\/html>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Industrial Linear Motion Control Linear Electric Actuator Control Valve A linear electric actuator control valve package designed for accurate valve-stem positioning, dependable modulating service and automated process control in HVAC, water treatment, power, chemical and general industrial systems. Related solutions: Linear Electric Actuator, Electric Linear Actuator Control Valve, Modulating Control Valve, Electric Actuated Globe Valve, Linear Valve Actuator and 381LS Electric Actuator. Request a Quote View Model Data 800\u201326,000 N Available thrust range 30 \/ 60 \/ 100 mm Maximum stroke options 4\u201320 mA or 1\u20135 V Input signal options \u00b11% Accuracy Reference control accuracy Overview Advantages Technical Data Model Selection Drawings Dimensions Mounting Brackets Applications Selection Guide Linear electric actuation for precise control-valve stem positioning Product Overview Accurate Linear Positioning for Automated Control Valves The 381LS series linear electric actuator converts an electrical command signal into controlled linear stem travel. It can be combined with globe valves and other compatible regulating valves through a selected mounting bracket and stem connection. 01 Closed-loop modulating control: accepts standard process signals and provides position feedback for automation systems. 02 Wide thrust coverage: models range from 800 N to 26,000 N for different valve sizes and shutoff loads. 03 Flexible stroke adjustment: zero point and operating stroke can be adjusted to match the connected valve. 04 Valve package compatibility: multiple bracket codes support a range of common control-valve diameters. Product Advantages Why Choose a Linear Electric Actuator Control Valve The actuator package is configured around required thrust, speed, stroke, valve size, control signal and installation environment. 01 Precision Modulating Control Reference basic error, hysteresis and dead zone are each controlled within the specified catalog limits for repeatable valve positioning. 02 Multiple Thrust and Stroke Options Eight catalog models cover 800 N to 26,000 N with 30 mm, 60 mm or 100 mm maximum travel options. 03 Standard Automation Signals Supports DC 4\u201320 mA or DC 1\u20135 V command signals and DC 4\u201320 mA output feedback. 04 Broad Power-Supply Compatibility AC and DC power options are available for different regions, control panels and industrial electrical standards. 05 Configurable Mounting Brackets Bracket codes A-2 through C-6 support multiple valve diameter ranges and stem-thread arrangements. Main Technical Parameters Electrical, Signal and Control Specifications The following values are translated from the supplied actuator manual and should be confirmed for the final ordered model. 01 Power Supply and Consumption Single-Phase AC AC 110 V 50\/60 Hz; AC 220 V 50\/60 Hz; AC 240 V 60 Hz Three-Phase AC AC 380 V 50 Hz DC Supply DC 24 V, DC 36 V, DC 48 V Type A Consumption 50 VA at rated load Type B Consumption 150 VA at rated load Type C Consumption 220 VA at rated load 02 Signals, Accuracy and Stroke Input Signal DC 4\u201320 mA or DC 1\u20135 V Output Signal DC 4\u201320 mA, load resistance \u2264 500 \u03a9 Basic Error \u00b11% Hysteresis \u2264 1% Dead Zone \u2264 1% Zero Adjustment \u00b125% Stroke Adjustment 20%\u2013100% Power-supply notes: Type C models have higher power consumption and are not offered with nominal DC 24 V, DC 36 V or DC 48 V supply. Supply-voltage deviation should remain within \u00b110%. Specify rated voltage and frequency when ordering. External Wiring Recommended Cable Arrangement Use shielded cable for input and output signals. Do not route the power conductors and signal conductors in the same cable. Item Standard S-Type Actuator Power Cable 3-core, 1.5 mm\u00b2 Signal Cable 4-core, 1.5 mm\u00b2 Cable Entry 2 \u00d7 M20 \u00d7 1.5 Environmental Conditions Reference Operating Environment Confirm enclosure, heater and site conditions before selecting the actuator package. Condition Standard S-Type Actuator Temperature, No Heater -10\u00b0C to 60\u00b0C Temperature, With Heater -35\u00b0C to 60\u00b0C Relative Humidity \u2264 95% Ambient Gas Non-corrosive gas Mechanical Vibration \u2264 1.5 g Series Selection 381LS Linear Electric Actuator Model Range Select the actuator according to required thrust, operating speed, valve travel and shutoff force. Model Output Thrust (N) Operating Speed (mm\/s) Maximum Stroke (mm) 381LSA-08 800 4.2 30 381LSA-20 2,000 2.1 30 381LSB-30 3,000 3.5 60 381LSB-50 5,000 1.7 60 381LSC-65 6,500 2.8 100 381LSC-99 10,000 2.0 100 381LSC-160 16,000 1.0 100 381LSC-260 26,000 1.0 100 Verify that actuator thrust is sufficient for valve shutoff differential pressure, packing friction and required safety margin. Actuator Drawings 381LSA \/ 381LSB and 381LSC Outline Views Two drawing panels are retained to separate the A\/B actuator body from the larger C-series configuration. Replace the URLs with final English engineering drawings. 01 381LSA \/ 381LSB Outline Drawing 02 381LSC Outline Drawing Overall Dimensions 381LS Actuator Dimension Reference Dimension symbols correspond to the actuator outline drawings. Values are in millimetres unless otherwise stated. Model D1 D2 H1 h1 h2 d1 d2 d3 C K M W Y O F R X Weight (kg) 381LSA \u00d8225 \u00d8260 200 78 18 \u00d890 \u00d870 \u00d855 M14 \u00d7 1.5 15 M8 28 87 10 12 80 75 12 381LSB \u00d8255 \u00d8290 280 125 31 \u00d8125 \u00d8102 \u00d870 M18 \u00d7 1.5 18 M10 45 90 10 15 100 91 22 381LSC \u00d8310 \u00d8360 415 175 31 \u00d8150 \u00d8125 \u00d885 M22 \u00d7 1.5 24 M12 \u2014 90 10 15 160 120 55 Dimension W is not specified for the 381LSC row in the supplied catalog image. Confirm the final approved production drawing before manufacturing the mounting structure. Mounting Brackets Actuator-to-Control-Valve Bracket Selection Each actuator model may be paired with two or three bracket sizes according to the connected control-valve diameter. Always verify actuator thrust against valve opening and closing force. Model and Valve Diameter Compatibility Actuator Model Control Valve Diameter (DN) Bracket Code 381LSA-08 20 A-2 381LSA-20 20\u201350 A-2 381LSB-30 25\u201350 B-3 381LSB-30 65\u2013100 B-4 381LSB-50 25\u201350 B-3 381LSB-50 65\u2013100 B-4 381LSB-50 125\u2013150 B-5 381LSC-65 65\u2013100 C-4 381LSC-65 125\u2013200 C-5 381LSC-99 125\u2013200 C-5 381LSC-99 250\u2013300 C-6 381LSC-160 125\u2013200 C-5 381LSC-260 125\u2013200 C-5 381LSC-400 250\u2013300 C-6 Reference bracket and valve connection arrangement Bracket Connection Dimensions Bracket Code L L1 D n-d1 D2 H D3 L2 A-2 173 78 \u00d880 4-\u00d810 \u00d860 130 100 17 B-3 215 125 \u00d880 4-\u00d810 \u00d860 157 125 21<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-11307","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages\/11307","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/comments?post=11307"}],"version-history":[{"count":4,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages\/11307\/revisions"}],"predecessor-version":[{"id":11317,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages\/11307\/revisions\/11317"}],"wp:attachment":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/media?parent=11307"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}