{"id":11296,"date":"2026-07-23T07:26:50","date_gmt":"2026-07-23T07:26:50","guid":{"rendered":"https:\/\/www.fleyendavalve.com\/?page_id=11296"},"modified":"2026-07-23T08:28:29","modified_gmt":"2026-07-23T08:28:29","slug":"electric-actuator-v-port-ball-valve","status":"publish","type":"page","link":"https:\/\/www.fleyendavalve.com\/pt\/electric-actuator-v-port-ball-valve\/","title":{"rendered":"Electric Actuator V Port Ball Valve"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"11296\" class=\"elementor elementor-11296\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2352b19 e-flex e-con-boxed wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no wpr-column-slider-no wpr-equal-height-no e-con e-parent\" data-id=\"2352b19\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-04e342d e-con-full e-flex wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no wpr-column-slider-no wpr-equal-height-no e-con e-parent\" data-id=\"04e342d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5155fc4 elementor-widget elementor-widget-html\" data-id=\"5155fc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<!DOCTYPE html>\r\n\r\n<html lang=\"en\">\r\n<head>\r\n<meta charset=\"utf-8\"\/>\r\n<meta content=\"width=device-width, initial-scale=1\" name=\"viewport\"\/>\r\n<!-- Keep the HTML and CSS files in the same directory. -->\r\n<link href=\"electric_actuator_v_port_ball_valve_product_page.css?v=20260723-1\" rel=\"stylesheet\"\/>\r\n<\/head>\r\n<body class=\"vpb-body\">\r\n<main class=\"vpb-page\">\r\n<!-- HERO -->\r\n<section class=\"vpb-hero\">\r\n<div class=\"vpb-container vpb-hero-grid\">\r\n<div class=\"vpb-hero-copy\">\r\n<p class=\"vpb-eyebrow\">Precision Electric Flow Control<\/p>\r\n<h1>Electric Actuator V Port Ball Valve<\/h1>\r\n<p class=\"vpb-lead\">A flanged V port ball valve with electric actuator for accurate throttling, stable flow regulation and automated pipeline control in water, HVAC, chemical, energy and industrial process systems.<\/p>\r\n<p class=\"vpb-keyword-line\">Related solutions: <strong>V Port Ball Valve<\/strong>, <strong>Electric V Port Ball Valve<\/strong>, <strong>Motorized V Port Ball Valve<\/strong>, <strong>V Notch Ball Valve<\/strong>, <strong>Flanged V Port Control Valve<\/strong> and <strong>Modulating Ball Valve<\/strong>.<\/p>\r\n<div class=\"vpb-hero-actions\">\r\n<a class=\"vpb-btn vpb-btn--primary\" href=\"mailto:inquiry@fleyendaflow.com\">\r\n              Request a Quote\r\n            <\/a>\r\n<a class=\"vpb-btn vpb-btn--secondary\" href=\"#vpb-dimensions\">\r\n              View Dimensions\r\n            <\/a>\r\n<\/div>\r\n<div aria-label=\"Key product data\" class=\"vpb-hero-facts\">\r\n<div class=\"vpb-hero-fact\">\r\n<b>DN25\u2013DN200<\/b>\r\n<span>Catalog size range<\/span>\r\n<\/div>\r\n<div class=\"vpb-hero-fact\">\r\n<b>PN1.6 MPa<\/b>\r\n<span>Reference pressure class<\/span>\r\n<\/div>\r\n<div class=\"vpb-hero-fact\">\r\n<b>V-Port Throttling<\/b>\r\n<span>Precision flow characteristic<\/span>\r\n<\/div>\r\n<div class=\"vpb-hero-fact\">\r\n<b>On\/Off or Modulating<\/b>\r\n<span>Electric actuator control<\/span>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"vpb-product-visual\">\r\n<!-- Replace the URL below with a transparent-background product image. -->\r\n<img decoding=\"async\" alt=\"Electric Actuator V Port Ball Valve\" src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-5.webp\"\/>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n<!-- MOBILE-FRIENDLY HORIZONTAL ANCHOR NAV -->\r\n<nav aria-label=\"Product page sections\" class=\"vpb-section-nav\">\r\n<div class=\"vpb-container vpb-section-nav-inner\"><a href=\"#vpb-overview\">Overview<\/a><a href=\"#vpb-advantages\">Advantages<\/a><a href=\"#vpb-specifications\">Specifications<\/a><a href=\"#vpb-materials\">Materials<\/a><a href=\"#vpb-drawings\">Drawings<\/a><a href=\"#vpb-dimensions\">Dimensions<\/a><a href=\"#vpb-applications\">Applications<\/a><a href=\"#vpb-selection\">Guia de Sele\u00e7\u00e3o<\/a><\/div>\r\n<\/nav>\r\n<!-- OVERVIEW -->\r\n<section class=\"vpb-section\" id=\"vpb-overview\">\r\n<div class=\"vpb-container vpb-overview-grid\">\r\n<figure class=\"vpb-media\">\r\n<!-- Replace with a valve detail, cutaway or installed product image. -->\r\n<img decoding=\"async\" alt=\"Electric V port ball valve detail\" src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-6.webp\"\/>\r\n<figcaption>V-shaped ball opening for controlled throttling and repeatable flow adjustment<\/figcaption>\r\n<\/figure>\r\n<div>\r\n<p class=\"vpb-eyebrow\">Product Overview<\/p>\r\n<h2>Electric V-Port Control for Modulating Pipeline Service<\/h2>\r\n<p class=\"vpb-lead\">The electric actuator V port ball valve uses a specially shaped ball opening to provide more controllable flow regulation than a conventional full-port ball valve. The actuator enables remote opening, closing and proportional position control for automated process systems.<\/p>\r\n<ul class=\"vpb-key-points\">\r\n<li>\r\n<span>01<\/span>\r\n<div><strong>Improved throttling control:<\/strong> the V-shaped port supports gradual flow-area change through the valve stroke.<\/div>\r\n<\/li>\r\n<li>\r\n<span>02<\/span>\r\n<div><strong>Electric automation:<\/strong> suitable for remote operation, PLC integration and position feedback.<\/div>\r\n<\/li>\r\n<li>\r\n<span>03<\/span>\r\n<div><strong>Flanged pipeline connection:<\/strong> provides stable installation and straightforward alignment.<\/div>\r\n<\/li>\r\n<li>\r\n<span>04<\/span>\r\n<div><strong>Configurable materials:<\/strong> carbon steel, stainless steel and multiple sealing combinations are available.<\/div>\r\n<\/li>\r\n<\/ul>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n<!-- ADVANTAGES -->\r\n<section class=\"vpb-section vpb-section--soft\" id=\"vpb-advantages\">\r\n<div class=\"vpb-container\">\r\n<p class=\"vpb-eyebrow\">Product Advantages<\/p>\r\n<h2>Why Choose a Motorized V Port Ball Valve<\/h2>\r\n<p class=\"vpb-lead vpb-copy-limit\">The valve is designed for automated throttling duties where repeatable positioning, secure shutoff and reliable electric actuation are required.<\/p>\r\n<div class=\"vpb-advantages\">\r\n<article class=\"vpb-advantage-row\">\r\n<div class=\"vpb-number\">01<\/div>\r\n<h3>More Controlled Flow Adjustment<\/h3>\r\n<p>The V-port opening changes the effective flow area progressively, supporting more stable regulation than a standard round-port ball valve.<\/p>\r\n<\/article>\r\n<article class=\"vpb-advantage-row\">\r\n<div class=\"vpb-number\">02<\/div>\r\n<h3>Remote Electric Operation<\/h3>\r\n<p>Configure the actuator for on\/off duty or modulating control with the required power supply, input signal and feedback functions.<\/p>\r\n<\/article>\r\n<article class=\"vpb-advantage-row\">\r\n<div class=\"vpb-number\">03<\/div>\r\n<h3>Reliable Flanged Installation<\/h3>\r\n<p>The flanged valve body provides stable connection for industrial pipelines, equipment skids and automated process systems.<\/p>\r\n<\/article>\r\n<article class=\"vpb-advantage-row\">\r\n<div class=\"vpb-number\">04<\/div>\r\n<h3>Multiple Body and Trim Materials<\/h3>\r\n<p>WCB, CF8, CF8M, CF3 and CF3M body options can be combined with compatible ball, stem, seal and packing materials.<\/p>\r\n<\/article>\r\n<article class=\"vpb-advantage-row\">\r\n<div class=\"vpb-number\">05<\/div>\r\n<h3>Broad Industrial Application Range<\/h3>\r\n<p>Suitable for water, HVAC, chemical, energy and general process applications after confirming medium compatibility and operating conditions.<\/p>\r\n<\/article>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n<!-- GB \/ ANSI TECHNICAL STANDARDS -->\r\n<section class=\"vpb-section\" id=\"vpb-specifications\">\r\n<div class=\"vpb-container\">\r\n<p class=\"vpb-eyebrow\">Technical Specifications<\/p>\r\n<h2>Electric V Port Ball Valve Configuration<\/h2>\r\n<p class=\"vpb-lead vpb-copy-limit\">Final valve and actuator selection should be confirmed according to size, pressure, medium, temperature, control signal and required flow characteristic.<\/p>\r\n<div class=\"vpb-standard-layout\">\r\n<div class=\"vpb-standard-column\">\r\n<div class=\"vpb-standard-heading\">\r\n<span>V-Port<\/span>\r\n<h3>Valve Configuration<\/h3>\r\n<\/div>\r\n<dl class=\"vpb-spec-table\">\r\n<div class=\"vpb-spec-line\">\r\n<dt>Product Type<\/dt>\r\n<dd>Electric Actuator V Port Ball Valve<\/dd>\r\n<\/div>\r\n<div class=\"vpb-spec-line\">\r\n<dt>Nominal Diameter<\/dt>\r\n<dd>DN25\u2013DN200<\/dd>\r\n<\/div>\r\n<div class=\"vpb-spec-line\">\r\n<dt>Reference Pressure<\/dt>\r\n<dd>PN1.6 MPa<\/dd>\r\n<\/div>\r\n<div class=\"vpb-spec-line\">\r\n<dt>Connection<\/dt>\r\n<dd>Flanged Type<\/dd>\r\n<\/div>\r\n<\/dl>\r\n<\/div>\r\n<div class=\"vpb-standard-column\">\r\n<div class=\"vpb-standard-heading\">\r\n<span>V-Port<\/span>\r\n<h3>Materials &amp; Control<\/h3>\r\n<\/div>\r\n<dl class=\"vpb-spec-table\">\r\n<div class=\"vpb-spec-line\">\r\n<dt>Flow Element<\/dt>\r\n<dd>V-Port \/ V-Notch Ball<\/dd>\r\n<\/div>\r\n<div class=\"vpb-spec-line\">\r\n<dt>Actuator Control<\/dt>\r\n<dd>On\/Off or Modulating<\/dd>\r\n<\/div>\r\n<div class=\"vpb-spec-line\">\r\n<dt>Body Materials<\/dt>\r\n<dd>WCB, CF8, CF8M, CF3, CF3M<\/dd>\r\n<\/div>\r\n<div class=\"vpb-spec-line\">\r\n<dt>Stem Materials<\/dt>\r\n<dd>17-4PH, SS316<\/dd>\r\n<\/div>\r\n<\/dl>\r\n<\/div>\r\n<\/div>\r\n<p class=\"vpb-note\">Confirm the final approved valve specification, actuator torque and control package before ordering.<\/p>\r\n<\/div>\r\n<\/section>\r\n<!-- MATERIALS -->\r\n<section class=\"vpb-section vpb-section--soft\" id=\"vpb-materials\">\r\n<div class=\"vpb-container\">\r\n<p class=\"vpb-eyebrow\">Main Parts Materials<\/p>\r\n<h2>Component and Material Reference<\/h2>\r\n<p class=\"vpb-lead vpb-copy-limit\">The following material data is reproduced from the supplied product catalog. Final materials should be selected according to medium, temperature, pressure and corrosion conditions.<\/p>\r\n<div class=\"vpb-table-wrap\">\r\n<table class=\"vpb-data-table vpb-material-table\"><thead><tr><th>No.<\/th><th>Component<\/th><th>Qty<\/th><th>Material<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Body<\/td><td>1<\/td><td>WCB, CF8, CF8M, CF3, CF3M<\/td><\/tr><tr><td>2<\/td><td>Ball<\/td><td>1<\/td><td>CF8, CF8M, hard chrome or high-velocity coating<\/td><\/tr><tr><td>3<\/td><td>After Stem<\/td><td>1<\/td><td>17-4PH, SS316<\/td><\/tr><tr><td>4<\/td><td>Cylindrical Pin<\/td><td>1<\/td><td>SS304, SS316<\/td><\/tr><tr><td>5<\/td><td>Before Stem<\/td><td>2<\/td><td>17-4PH, SS316<\/td><\/tr><tr><td>6<\/td><td>Spline<\/td><td>1<\/td><td>17-4PH, SS316<\/td><\/tr><tr><td>7<\/td><td>Flat Key<\/td><td>1<\/td><td>SS304, 45# steel<\/td><\/tr><tr><td>8<\/td><td>After Gland<\/td><td>1<\/td><td>CF8, CF8M<\/td><\/tr><tr><td>9<\/td><td>O-Ring<\/td><td>1<\/td><td>Viton<\/td><\/tr><tr><td>10<\/td><td>Adjust Pad<\/td><td>1 spare<\/td><td>PTFE<\/td><\/tr><tr><td>11<\/td><td>Self-Lubricating Bearing<\/td><td>1<\/td><td>Composite Material<\/td><\/tr><tr><td>12<\/td><td>Self-Lubricating Bearing<\/td><td>1<\/td><td>Composite Material<\/td><\/tr><tr><td>13<\/td><td>Packing<\/td><td>1 set<\/td><td>PTFE<\/td><\/tr><tr><td>14<\/td><td>Gland<\/td><td>1<\/td><td>CF8<\/td><\/tr><tr><td>15<\/td><td>O-Ring<\/td><td>1<\/td><td>Viton<\/td><\/tr><tr><td>16<\/td><td>Seal Block<\/td><td>1<\/td><td>PTFE, CF8, CF8M with hard chrome or high-velocity coating<\/td><\/tr><tr><td>17<\/td><td>Seal Block Spring<\/td><td>1<\/td><td>SS316<\/td><\/tr><tr><td>18<\/td><td>Sealing Lid<\/td><td>1<\/td><td>Q235, SS304, SS316<\/td><\/tr><tr><td>19<\/td><td>Inner Hexagon Screw<\/td><td>\u2014<\/td><td>SS304<\/td><\/tr><tr><td>20<\/td><td>Hexagon Screw<\/td><td>4<\/td><td>SS304<\/td><\/tr><\/tbody><\/table>\r\n<\/div>\r\n<p class=\"vpb-note\">Materials are for reference. Confirm the final approved bill of materials for the selected valve configuration and operating conditions.<\/p>\r\n<\/div>\r\n<\/section>\r\n<!-- DIMENSIONS -->\r\n<section class=\"vpb-section\" id=\"vpb-drawings\"><div class=\"vpb-container\"><p class=\"vpb-eyebrow\">Technical Drawings<\/p><h2>Valve Construction and Outline Drawings<\/h2><p class=\"vpb-lead vpb-copy-limit\">Two drawing panels are retained for product construction and dimensional reference. Replace the image URLs with your final engineering drawings.<\/p><div class=\"vpb-drawing-block\">\r\n<div class=\"vpb-drawing-heading\">\r\n<div>\r\n<p class=\"vpb-eyebrow\">Technical Drawing<\/p>\r\n<h3>Construction and Dimensional Reference<\/h3>\r\n<\/div>\r\n<p>Use the first panel for an exploded or construction drawing and the second panel for the outline and actuator dimensions.<\/p>\r\n<\/div>\r\n<div class=\"vpb-drawing-layout\">\r\n<figure class=\"vpb-drawing-view vpb-drawing-view--front\">\r\n<div class=\"vpb-drawing-view-label\">\r\n<span>01<\/span>\r\n<strong>Construction \/ Exploded View<\/strong>\r\n<\/div>\r\n<div class=\"vpb-drawing-image-wrap\">\r\n<img decoding=\"async\" alt=\"V port ball valve construction drawing\" src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-4.webp\"\/>\r\n<\/div>\r\n<\/figure>\r\n<div class=\"vpb-drawing-side-column\">\r\n<figure class=\"vpb-drawing-view vpb-drawing-view--side\">\r\n<div class=\"vpb-drawing-view-label\">\r\n<span>02<\/span>\r\n<strong>Outline \/ Dimensional View<\/strong>\r\n<\/div>\r\n<div class=\"vpb-drawing-image-wrap\">\r\n<img decoding=\"async\" alt=\"Electric actuator V port ball valve outline drawing\" src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/07\/3-3-1.webp\"\/>\r\n<\/div>\r\n<\/figure>\r\n<div class=\"vpb-drawing-key\">\r\n<p class=\"vpb-drawing-key-title\">Drawing Symbols<\/p>\r\n<div aria-label=\"Dimension symbols\" class=\"vpb-drawing-symbols\">\r\n<span>A<\/span>\r\n<span>B<\/span>\r\n<span>C<\/span>\r\n<span>G<\/span>\r\n<span>Y<\/span>\r\n<span>b<\/span>\r\n<span>f<\/span>\r\n<span>L<\/span>\r\n<span>H<\/span>\r\n<\/div>\r\n<p>Refer to the PN1.6 MPa table for exact A, B, C, G, Y, b, f, L, H, H1 and H2 values.<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div><\/div><\/section><section class=\"vpb-section\" id=\"vpb-dimensions\">\r\n<div class=\"vpb-container\">\r\n<p class=\"vpb-eyebrow\">Outline Dimensions<\/p>\r\n<h2>PN1.6 MPa Main Outline and Connecting Flange Size<\/h2>\r\n<p class=\"vpb-lead vpb-copy-limit\">Reference dimensions reproduced from the supplied catalog. Values are in millimetres unless otherwise stated.<\/p>\r\n\r\n<div class=\"vpb-dimension-group\">\r\n<div class=\"vpb-dimension-title\">\r\n<span>PN1.6 MPa<\/span>\r\n<h3>Main Outline and Connecting Flange Size<\/h3>\r\n<\/div>\r\n<div class=\"vpb-table-wrap\">\r\n<table class=\"vpb-data-table\"><thead><tr><th>Dimension<\/th><th>DN25<\/th><th>DN32<\/th><th>DN40<\/th><th>DN50<\/th><th>DN65<\/th><th>DN80<\/th><th>DN100<\/th><th>DN125<\/th><th>DN150<\/th><th>DN200<\/th><\/tr><\/thead><tbody><tr><th>Inch<\/th><td>1\"<\/td><td>1-1\/4\"<\/td><td>1-1\/2\"<\/td><td>2\"<\/td><td>2-1\/2\"<\/td><td>3\"<\/td><td>4\"<\/td><td>5\"<\/td><td>6\"<\/td><td>8\"<\/td><\/tr><tr><th>A<\/th><td>115<\/td><td>140<\/td><td>150<\/td><td>165<\/td><td>185<\/td><td>200<\/td><td>220<\/td><td>250<\/td><td>285<\/td><td>340<\/td><\/tr><tr><th>B<\/th><td>65<\/td><td>76<\/td><td>84<\/td><td>99<\/td><td>118<\/td><td>132<\/td><td>156<\/td><td>184<\/td><td>211<\/td><td>266<\/td><\/tr><tr><th>C<\/th><td>38<\/td><td>45<\/td><td>50<\/td><td>62<\/td><td>73<\/td><td>90<\/td><td>115<\/td><td>134<\/td><td>164<\/td><td>206<\/td><\/tr><tr><th>G<\/th><td>20<\/td><td>25<\/td><td>32<\/td><td>40<\/td><td>55<\/td><td>62<\/td><td>80<\/td><td>100<\/td><td>125<\/td><td>155<\/td><\/tr><tr><th>Y<\/th><td>85<\/td><td>100<\/td><td>110<\/td><td>125<\/td><td>145<\/td><td>160<\/td><td>180<\/td><td>210<\/td><td>240<\/td><td>295<\/td><\/tr><tr><th>b<\/th><td>16<\/td><td>18<\/td><td>18<\/td><td>20<\/td><td>20<\/td><td>20<\/td><td>22<\/td><td>22<\/td><td>24<\/td><td>24<\/td><\/tr><tr><th>f<\/th><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><td>2<\/td><\/tr><tr><th>n-\u03c6d<\/th><td>4-\u03c614<\/td><td>4-\u03c618<\/td><td>4-\u03c618<\/td><td>4-\u03c618<\/td><td>8-\u03c618<\/td><td>8-\u03c618<\/td><td>8-\u03c618<\/td><td>8-\u03c618<\/td><td>8-\u03c622<\/td><td>12-\u03c622<\/td><\/tr><tr><th>L<\/th><td>102<\/td><td>102<\/td><td>114<\/td><td>124<\/td><td>145<\/td><td>165<\/td><td>194<\/td><td>194<\/td><td>229<\/td><td>243<\/td><\/tr><tr><th>H<\/th><td>81<\/td><td>86<\/td><td>90<\/td><td>93<\/td><td>108<\/td><td>123<\/td><td>138<\/td><td>128<\/td><td>170<\/td><td>200<\/td><\/tr><tr><th>H1<\/th><td>178<\/td><td>183<\/td><td>185<\/td><td>195<\/td><td>210<\/td><td>223<\/td><td>235<\/td><td>250<\/td><td>270<\/td><td>320<\/td><\/tr><tr><th>H2<\/th><td>28<\/td><td>30<\/td><td>30<\/td><td>26<\/td><td>28<\/td><td>31<\/td><td>33<\/td><td>25<\/td><td>31<\/td><td>31<\/td><\/tr><\/tbody><\/table>\r\n<\/div>\r\n<\/div>\r\n\r\n\r\n\r\n\r\n<p class=\"vpb-note\">Dimensions are for reference only. Confirm the final approved production drawing for the selected valve size, flange standard and actuator configuration.<\/p>\r\n<\/div>\r\n<\/section>\r\n<!-- APPLICATIONS -->\r\n<section class=\"vpb-section vpb-section--soft\" id=\"vpb-applications\">\r\n<div class=\"vpb-container vpb-application-layout\">\r\n<div>\r\n<p class=\"vpb-eyebrow\">Typical Applications<\/p>\r\n<h2>Industrial Applications for V Port Ball Valves<\/h2>\r\n<p class=\"vpb-lead\">The valve is suitable for automated throttling and flow regulation where repeatable electric positioning and a secure flanged connection are required.<\/p>\r\n<div class=\"vpb-application-list\">\r\n<div class=\"vpb-application-item\">\r\n<strong>Water Treatment<\/strong>\r\n<span>Process water, filtration, distribution and dosing systems.<\/span>\r\n<\/div>\r\n<div class=\"vpb-application-item\">\r\n<strong>HVAC Systems<\/strong>\r\n<span>Chilled water, hot water and building utility control loops.<\/span>\r\n<\/div>\r\n<div class=\"vpb-application-item\">\r\n<strong>Chemical Processing<\/strong>\r\n<span>Compatible chemical and process-media flow regulation.<\/span>\r\n<\/div>\r\n<div class=\"vpb-application-item\">\r\n<strong>Power and Energy<\/strong>\r\n<span>Cooling, auxiliary and plant-service pipeline control.<\/span>\r\n<\/div>\r\n<div class=\"vpb-application-item\">\r\n<strong>Industrial Automation<\/strong>\r\n<span>PLC-controlled skids, equipment packages and process lines.<\/span>\r\n<\/div>\r\n<div class=\"vpb-application-item\">\r\n<strong>General Process Service<\/strong>\r\n<span>Automated throttling where a V-notch flow characteristic is preferred.<\/span>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<figure class=\"vpb-application-image\">\r\n<!-- Replace with one clean application or installation image. -->\r\n<img decoding=\"async\" alt=\"Electric V port ball valve application\" src=\"https:\/\/www.fleyendavalve.com\/wp-content\/uploads\/2026\/03\/\u77f3\u6cb9\u5382.jpg\"\/>\r\n<\/figure>\r\n<\/div>\r\n<\/section>\r\n<!-- SELECTION -->\r\n<section class=\"vpb-section\" id=\"vpb-selection\">\r\n<div class=\"vpb-container\">\r\n<p class=\"vpb-eyebrow\">Guia de Sele\u00e7\u00e3o<\/p>\r\n<h2>How to Select the Correct V Port Ball Valve<\/h2>\r\n<p class=\"vpb-lead vpb-copy-limit\">Confirm the required flow characteristic, materials, pressure class and actuator control before quotation and drawing approval.<\/p>\r\n<div class=\"vpb-selection-table\">\r\n<article class=\"vpb-selection-row\">\r\n<small>Flow Control<\/small>\r\n<h3>V-Port Opening Profile<\/h3>\r\n<p>Confirm the required control characteristic and operating range for the process.<\/p>\r\n<\/article>\r\n<article class=\"vpb-selection-row\">\r\n<small>Actuation<\/small>\r\n<h3>On\/Off or Modulating Electric Actuator<\/h3>\r\n<p>Select two-position operation for isolation or proportional control for throttling service.<\/p>\r\n<\/article>\r\n<article class=\"vpb-selection-row\">\r\n<small>Materials<\/small>\r\n<h3>Carbon Steel or Stainless Steel<\/h3>\r\n<p>Match body, ball, stem, seal and packing materials to the medium and temperature.<\/p>\r\n<\/article>\r\n<article class=\"vpb-selection-row\">\r\n<small>Controls<\/small>\r\n<h3>Voltage, Signal and Feedback<\/h3>\r\n<p>Confirm power supply, input signal, position feedback and communication requirements.<\/p>\r\n<\/article>\r\n<article class=\"vpb-selection-row\">\r\n<small>Installation<\/small>\r\n<h3>Pipeline and Site Conditions<\/h3>\r\n<p>Provide flange standard, installation position and environmental protection requirements.<\/p>\r\n<\/article>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n<!-- ORDERING -->\r\n<section class=\"vpb-section vpb-section--soft\">\r\n<div class=\"vpb-container vpb-order-guide\">\r\n<div>\r\n<p class=\"vpb-eyebrow\">Ordering Information<\/p>\r\n<h2>Information Required for Valve Selection<\/h2>\r\n<p class=\"vpb-lead\">Complete project data helps determine the valve body, V-port configuration, actuator torque and control package.<\/p>\r\n<\/div>\r\n<div class=\"vpb-order-steps\">\r\n<div class=\"vpb-order-step\">\r\n<div>\r\n<strong>Nominal diameter and pressure class<\/strong>\r\n<span>For example DN100, PN1.6 MPa and the required flange standard.<\/span>\r\n<\/div>\r\n<\/div>\r\n<div class=\"vpb-order-step\">\r\n<div>\r\n<strong>Medium, flow and temperature<\/strong>\r\n<span>State the process medium, normal flow range and operating temperature.<\/span>\r\n<\/div>\r\n<\/div>\r\n<div class=\"vpb-order-step\">\r\n<div>\r\n<strong>Body, ball and sealing materials<\/strong>\r\n<span>Select carbon steel or stainless steel with compatible trim and seals.<\/span>\r\n<\/div>\r\n<\/div>\r\n<div class=\"vpb-order-step\">\r\n<div>\r\n<strong>Actuator voltage and control mode<\/strong>\r\n<span>Confirm on\/off or modulating duty, input signal and feedback requirements.<\/span>\r\n<\/div>\r\n<\/div>\r\n<div class=\"vpb-order-step\">\r\n<div>\r\n<strong>Installation environment<\/strong>\r\n<span>Provide indoor, outdoor, wash-down or special protection requirements.<\/span>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section>\r\n<!-- CTA -->\r\n<section class=\"vpb-cta\">\r\n<div class=\"vpb-container vpb-cta-inner\">\r\n<div>\r\n<h2>Configure Your Electric Actuator V Port Ball Valve<\/h2>\r\n<p>Send the valve size, pressure, medium, flow range, materials, actuator voltage and control requirements for a suitable quotation and drawing.<\/p>\r\n<\/div>\r\n<a class=\"vpb-btn vpb-btn--light\" href=\"mailto:inquiry@fleyendaflow.com\">\r\n          Request a Quote\r\n        <\/a>\r\n<\/div>\r\n<\/section>\r\n<\/main>\r\n<\/body>\r\n<\/html>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Precision Electric Flow Control Electric Actuator V Port Ball Valve A flanged V port ball valve with electric actuator for accurate throttling, stable flow regulation and automated pipeline control in water, HVAC, chemical, energy and industrial process systems. Related solutions: V Port Ball Valve, Electric V Port Ball Valve, Motorized V Port Ball Valve, V Notch Ball Valve, Flanged V Port Control Valve and Modulating Ball Valve. Request a Quote View Dimensions DN25\u2013DN200 Catalog size range PN1.6 MPa Reference pressure class V-Port Throttling Precision flow characteristic On\/Off or Modulating Electric actuator control OverviewAdvantagesSpecificationsMaterialsDrawingsDimensionsApplicationsSelection Guide V-shaped ball opening for controlled throttling and repeatable flow adjustment Product Overview Electric V-Port Control for Modulating Pipeline Service The electric actuator V port ball valve uses a specially shaped ball opening to provide more controllable flow regulation than a conventional full-port ball valve. The actuator enables remote opening, closing and proportional position control for automated process systems. 01 Improved throttling control: the V-shaped port supports gradual flow-area change through the valve stroke. 02 Electric automation: suitable for remote operation, PLC integration and position feedback. 03 Flanged pipeline connection: provides stable installation and straightforward alignment. 04 Configurable materials: carbon steel, stainless steel and multiple sealing combinations are available. Product Advantages Why Choose a Motorized V Port Ball Valve The valve is designed for automated throttling duties where repeatable positioning, secure shutoff and reliable electric actuation are required. 01 More Controlled Flow Adjustment The V-port opening changes the effective flow area progressively, supporting more stable regulation than a standard round-port ball valve. 02 Remote Electric Operation Configure the actuator for on\/off duty or modulating control with the required power supply, input signal and feedback functions. 03 Reliable Flanged Installation The flanged valve body provides stable connection for industrial pipelines, equipment skids and automated process systems. 04 Multiple Body and Trim Materials WCB, CF8, CF8M, CF3 and CF3M body options can be combined with compatible ball, stem, seal and packing materials. 05 Broad Industrial Application Range Suitable for water, HVAC, chemical, energy and general process applications after confirming medium compatibility and operating conditions. Technical Specifications Electric V Port Ball Valve Configuration Final valve and actuator selection should be confirmed according to size, pressure, medium, temperature, control signal and required flow characteristic. V-Port Valve Configuration Product Type Electric Actuator V Port Ball Valve Nominal Diameter DN25\u2013DN200 Reference Pressure PN1.6 MPa Connection Flanged Type V-Port Materials &amp; Control Flow Element V-Port \/ V-Notch Ball Actuator Control On\/Off or Modulating Body Materials WCB, CF8, CF8M, CF3, CF3M Stem Materials 17-4PH, SS316 Confirm the final approved valve specification, actuator torque and control package before ordering. Main Parts Materials Component and Material Reference The following material data is reproduced from the supplied product catalog. Final materials should be selected according to medium, temperature, pressure and corrosion conditions. No. Component Qty Material 1 Body 1 WCB, CF8, CF8M, CF3, CF3M 2 Ball 1 CF8, CF8M, hard chrome or high-velocity coating 3 After Stem 1 17-4PH, SS316 4 Cylindrical Pin 1 SS304, SS316 5 Before Stem 2 17-4PH, SS316 6 Spline 1 17-4PH, SS316 7 Flat Key 1 SS304, 45# steel 8 After Gland 1 CF8, CF8M 9 O-Ring 1 Viton 10 Adjust Pad 1 spare PTFE 11 Self-Lubricating Bearing 1 Composite Material 12 Self-Lubricating Bearing 1 Composite Material 13 Packing 1 set PTFE 14 Gland 1 CF8 15 O-Ring 1 Viton 16 Seal Block 1 PTFE, CF8, CF8M with hard chrome or high-velocity coating 17 Seal Block Spring 1 SS316 18 Sealing Lid 1 Q235, SS304, SS316 19 Inner Hexagon Screw \u2014 SS304 20 Hexagon Screw 4 SS304 Materials are for reference. Confirm the final approved bill of materials for the selected valve configuration and operating conditions. Technical Drawings Valve Construction and Outline Drawings Two drawing panels are retained for product construction and dimensional reference. Replace the image URLs with your final engineering drawings. Technical Drawing Construction and Dimensional Reference Use the first panel for an exploded or construction drawing and the second panel for the outline and actuator dimensions. 01 Construction \/ Exploded View 02 Outline \/ Dimensional View Drawing Symbols A B C G Y b f L H Refer to the PN1.6 MPa table for exact A, B, C, G, Y, b, f, L, H, H1 and H2 values. Outline Dimensions PN1.6 MPa Main Outline and Connecting Flange Size Reference dimensions reproduced from the supplied catalog. Values are in millimetres unless otherwise stated. PN1.6 MPa Main Outline and Connecting Flange Size Dimension DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 Inch 1&#8243; 1-1\/4&#8243; 1-1\/2&#8243; 2&#8243; 2-1\/2&#8243; 3&#8243; 4&#8243; 5&#8243; 6&#8243; 8&#8243; A 115 140 150 165 185 200 220 250 285 340 B 65 76 84 99 118 132 156 184 211 266 C 38 45 50 62 73 90 115 134 164 206 G 20 25 32 40 55 62 80 100 125 155 Y 85 100 110 125 145 160 180 210 240 295 b 16 18 18 20 20 20 22 22 24 24 f 2 2 2 2 2 2 2 2 2 2 n-\u03c6d 4-\u03c614 4-\u03c618 4-\u03c618 4-\u03c618 8-\u03c618 8-\u03c618 8-\u03c618 8-\u03c618 8-\u03c622 12-\u03c622 L 102 102 114 124 145 165 194 194 229 243 H 81 86 90 93 108 123 138 128 170 200 H1 178 183 185 195 210 223 235 250 270 320 H2 28 30 30 26 28 31 33 25 31 31 Dimensions are for reference only. Confirm the final approved production drawing for the selected valve size, flange standard and actuator configuration. Typical Applications Industrial Applications for V Port Ball Valves The valve is suitable for automated throttling and flow regulation where repeatable electric positioning and a secure flanged connection are required. Water Treatment Process water, filtration, distribution and dosing systems. HVAC Systems Chilled water, hot water and building utility control loops. Chemical Processing Compatible chemical and process-media flow regulation. Power and Energy Cooling, auxiliary and plant-service pipeline control. Industrial Automation PLC-controlled skids, equipment packages and process lines. General Process Service Automated throttling where a V-notch<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-11296","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages\/11296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/comments?post=11296"}],"version-history":[{"count":4,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages\/11296\/revisions"}],"predecessor-version":[{"id":11306,"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/pages\/11296\/revisions\/11306"}],"wp:attachment":[{"href":"https:\/\/www.fleyendavalve.com\/pt\/wp-json\/wp\/v2\/media?parent=11296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}