The AW Double Acting / Single Acting (FC, FO) actuator uses a scotch-yoke mechanism, delivers high break torque with fail-safe positioning, ensures stable quarter-turn valve control in critical process lines, and is verified through ISO/VDI performance standards.
| Output Torque Range | Up to 350,000 Nm |
| Rotation Angle | 90° ± 5° |
| Ambient Temperature Range | –20°C to +80°C |
| Body Material | Ductile Iron / Carbon Steel |
| Connection Standard | ISO 5211, VDI/VDE 3845 |
| Actuator Type: | Pneumatic Scotch-Yoke, Double Acting / Spring Return (FC/FO) |
| Voltage Options | 24V DC, 110V AC, 220V AC |
| Control Signal Type | 3/5-Way Solenoid Valve, Limit Switch Feedback |
| Protection Grade | IP67 / Optional IP68 |
| Design Standard | ISO 5211, NAMUR |
| Testing Standard | EN 15714-3 |
| Certification | CE / RoHS / ISO 9001 / IP65 (Actuator) |
| Customization | Above Are Standard Parameter Samples. If You Have Specific Parameters And Materials, We Can Customize Them All. |
Certified Quality for Industrial Valve Applications
Fleyenda valves and electric actuators are built for stable performance, reliable operation, and long-term industrial use. With certified quality support, they are suitable for water treatment, chemical processing, automation, and industrial process control systems.
FAQs That 80% Users Interest
1. How do I decide whether the AW Double Acting / Single Acting (FC, FO) actuator suits my quarter-turn valve?
• Provides stable torque for pneumatic quarter-turn valves
• Double-acting fits high-cycle systems needing bidirectional power
• Spring-return FC/FO delivers automatic fail positioning
• Suitable for ball, butterfly, and plug valves requiring strong break torque
2. What’s the key difference between fail-close and fail-open in the AW Single Acting (FC, FO) actuator?
• Fail-close shuts the valve automatically during air loss
• Fail-open keeps flow paths open for venting or cooling lines
• Spring mechanism ensures mechanical fail-safe movement
• Choice depends on safety level, media type, and process requirements
3. What torque considerations matter when sizing an AW Double Acting pneumatic actuator?
• Supports high breakaway torque for tight-seated valves
• Requires valve torque plus a 20–30% safety factor
• Higher air pressure improves output and stroke reliability
• Prevents incomplete rotation and actuator stall when sized correctly
4. Is the AW pneumatic actuator compatible with industrial control systems?
• ISO/VDI interfaces allow direct mounting on multiple valve types
• Works with solenoid valves, limit switches, and feedback modules
• Accepts 24V DC, 110V AC, and 220V AC control input
• Integrates with PLC, SCADA, and emergency shutdown loops