Electric 3-Way UPVC Ball Valve
The FLE-Q-PD electric 3-way UPVC ball valve is designed for automated flow diversion and distribution in compatible water treatment, chemical dosing and industrial fluid systems. L-port and T-port configurations, together with union socket or female threaded connections, allow the valve to match different pipeline arrangements.

Automated Three-Way Flow Control for UPVC Piping
FLE-Q-PD combines a UPVC valve body with electric quarter-turn operation for compatible liquid-handling systems. Flow port and end connection are selected according to the required switching route and installation layout.
L-Port and T-Port Options
Select the port arrangement for branch diversion or the required multi-port distribution sequence.
UPVC Valve Construction
UPVC construction for compatible water, treatment chemicals and industrial process liquids.
Electric Quarter-Turn Actuation
Automated switching supports remote operation in equipment and process piping systems.
Socket or Threaded Ends
Union socket and female threaded connection options for different UPVC pipeline layouts.
ON/OFF or Regulating Options
Actuator control configuration can be selected according to the required operating sequence.
Compact Process Installation
Three-way flow switching for treatment skids, dosing equipment and compatible fluid systems.
L-Port vs T-Port: Select the Required Flow Route
The port configuration determines how the common line connects with the branch ports during valve operation. Confirm the required flow positions and pipeline connections before selecting the actuator arrangement.
- L-port: commonly selected to divert flow between two alternative branches.
- T-port: used for selected multi-port distribution or mixing arrangements.
- Union socket: for compatible UPVC socket pipeline connections.
- Female thread: for compatible threaded pipeline connections.
- Actuator setup: specify the required port positions and switching sequence.
FLE-Q-PD Technical Specifications
Review the valve construction, operating range, connection options and actuator configuration before specifying the product for your system.
| Parameter | Specification |
|---|---|
| Model | FLE-Q-PD |
| Valve type | Electric 3-way UPVC ball valve |
| Corpo da válvula | UPVC |
| Flow port | L-port / T-port |
| End connection | Union socket / female thread |
| Nominal size | DN15–DN100 |
| Pressão de trabalho | PN10 |
| Working temperature | 0°C to 60°C |
| Actuator type | Atuador elétrico de um quarto de volta |
| Operation | Automated three-way switching |
| Control mode | ON/OFF / regulating options |
| Power supply | AC / DC options according to actuator selection |
| Position control | Configured to the selected L-port / T-port arrangement |
| Applicable media | Water and compatible treatment chemicals or process liquids |
Electric Actuator & Control Configuration
Quarter-turn operation| Selection Item | Available Configuration | Selection Basis |
|---|---|---|
| Actuator type | Atuador elétrico de um quarto de volta | Matched to valve size and operating torque |
| Control mode | ON/OFF / regulating options | Required switching or control sequence |
| Power supply | AC / DC options | Site power supply and actuator model |
| Port position | L-port / T-port arrangement | Required flow route and port positions |
| Conexão | Union socket / female thread | Pipeline connection and installation layout |
Outline Drawing & Connection Dimensions
FLE-Q-PD electric 3-way UPVC ball valve outline and connection dimensions for installation planning and pipeline matching.
- Nominal sizes: DN15–DN50 dimensional data listed below.
- Connections: UPVC union socket / female thread configurations.
- Dimension unit: millimetres, unless otherwise indicated.

Main Outline and Connecting Dimensions
Dimensions: mm · G: inch| Tamanho | DN15 | DN20 | DN25 | DN32 | DN40 | DN50 |
|---|---|---|---|---|---|---|
| G | 1/2″ | 3/4″ | 1″ | 1-1/4″ | 1-1/2″ | 2″ |
| d | 14 | 22 | 25 | 25 | 38 | 38 |
| D | 20 | 25 | 32 | 40 | 50 | 63 |
| D1 | 30 | 36 | 45 | 55 | 64 | 77 |
| L1 | 22.8 | 25 | 28.5 | 32 | 34.8 | 38 |
| L | 137 | 172 | 200 | 208 | 240 | 246 |
| H | 53 | 65 | 68 | 68 | 92 | 92 |
Automated Flow Switching for Water and Chemical Systems
FLE-Q-PD is intended for compatible liquid-handling systems where automated branch switching, distribution or routing is required. Confirm fluid compatibility, operating temperature and pressure before specifying the valve.
Water Treatment & Distribution
Switch flow between selected treatment and utility branches.
- Filtration and water treatment skids
- Storage, transfer and distribution lines
- Automated process water routing
Chemical Dosing & Brine Systems
Route compatible treatment liquids in dosing and preparation systems.
- Chemical dosing and treatment equipment
- Brine and salt solution preparation
- OEM fluid handling and process skids
Applications of Electric 3-Way UPVC Ball Valves
Automated three-way flow switching for compatible water treatment, chemical dosing, brine preparation and industrial fluid handling equipment.

Tratamento de Água
Flow diversion across filtration, treatment and distribution lines.
Chemical Dosing
Automated routing for compatible treatment-liquid systems.

Brine & Salt Solutions
Flow switching in compatible brine preparation systems.

OEM Process Equipment
Three-way valve integration in fluid handling skids.
Information Required for Correct Valve Selection
Providing the pipeline and control details helps match the port configuration, connection type and electric actuator to the required operating sequence.
L-port or T-port, required flow route and operating positions.
DN size, connection type, pipe specification and installation layout.
Fluid composition, working pressure and operating temperature.
Power supply, ON/OFF or regulating mode and switching requirements.
Electric 3-Way UPVC Ball Valve FAQs
What is an electric 3-way UPVC ball valve used for?
It is used to automate flow diversion or distribution in compatible water treatment, chemical dosing and industrial fluid systems. The three-way configuration allows selected pipeline branches to be connected according to the valve port arrangement.
What is the difference between L-port and T-port configurations?
An L-port configuration is commonly used to divert flow between two alternative branches. A T-port configuration can support selected multi-port distribution or mixing arrangements. Confirm the required flow positions before ordering.
Which connection types are available?
The listed configurations include UPVC union socket and female threaded connections. Specify the required connection type and pipe details when requesting a quotation.
What are the available size, pressure and temperature ranges?
The listed product range is DN15–DN100, PN10 and 0°C to 60°C. The dimensional table on this page provides detailed dimensions for DN15–DN50.
Which actuator power supply and control modes are available?
AC and DC power supply options are available according to actuator selection. ON/OFF and regulating configurations can be specified; confirm the required control mode and power supply with the project requirements.
What information is needed for a quotation?
Provide valve size, L-port or T-port configuration, connection type, fluid, working pressure, temperature, actuator power supply, control mode and required quantity.
Need an Electric 3-Way UPVC Ball Valve?
Send your flow configuration, pipeline size and operating conditions for FLE-Q-PD selection.