تخطي الروابط
FLE-Q-F · General-Purpose Automated Isolation

صمام كروي كهربائي ثنائي الاتجاه بشفة

The FLE-Q-F Electric 2 Way Flange Ball Valve is built for dependable remote shutoff in industrial pipelines and equipment systems. A full-bore ball path minimizes pressure loss, while the flanged body and ISO 5211 electric actuator provide secure installation, repeatable 0–90° operation, and straightforward integration with PLC, relay, or centralized automation.

2-Way Full-Bore IsolationDN15–DN300PN16–PN40ANSI / DIN / JIS Flanges
النص
SS304 / 316 / WCB
درجة الحرارة
من −20 درجة مئوية إلى +180 درجة مئوية
Actuation
0–90° Electric
Protection
IP67 / IP68 Option
FLE-Q-F electric 2 way flange ball valve with electric actuator
Core dutyRemote open / close isolation for standard industrial process lines, skids and equipment.
Full BoreLow restriction when fully open
ذو حوافSecure pipeline connection
ElectricRemote automation without air supply
Core isolation function

Built for dependable automated shutoff

This is the general-purpose workhorse in the Fleyenda motorized ball valve range: a standard 2-way flanged ball valve optimized primarily for open-close isolation rather than continuous throttling.

For water, oil, gas, steam and compatible process fluids, the full-bore flow path helps reduce pressure loss when the valve is fully open. Electric actuation removes the need for a compressed-air network and makes the assembly practical for equipment OEMs, utility lines, treatment systems and remote pipeline isolation.

  • 01Reliable 0–90° quarter-turn operation for automated shutoff.
  • 02Full-bore passage supports high flow with low restriction.
  • 03Flanged ends suit permanent industrial piping and larger size ranges.
  • 04ISO 5211 mounting simplifies actuator matching, replacement and upgrades.
Automated industrial pipeline application for electric flanged ball valve
Remote pipeline isolationAutomated shutoff for process lines, utility systems and equipment skids.
Technical data

Electric 2 Way Flange Ball Valve specifications

Standard configurations cover common industrial sizes, flange standards, materials, voltages and actuator options. Final selection should match the real process conditions.

ModelFLE-Q-F
Size range½″–12″ / DN15–DN300
ضغط التشغيلPN16–PN40 / ANSI Class 150–300
Working temperature−20°C to +180°C, depending on seat and media
Body materialالفولاذ المقاوم للصدأ 304 / 316 أو الفولاذ الكربوني WCB
الاتصالFlanged — ANSI B16.5 / DIN PN16 / JIS 10K options
Applicable mediaWater, oil, air, gas, steam, weak acids and alkalis where material compatibility is confirmed
المشغلElectric quarter-turn actuator; on/off standard, selected modulating configurations available
Voltage options24 فولت تيار مستمر، 24 فولت تيار متردد، 110 فولت تيار متردد، 220 فولت تيار متردد، 380 فولت تيار متردد
Design referencesAPI 6D / GB/T 12237 / ISO 5211
الاختبارAPI 598 / GB/T 13927
Fire-safe optionAPI 607 selected configurations
ProtectionIP67 standard on selected actuators; IP68 optional
Explosion-proof optionSelected Ex d II BT4 / CT4 / CT6 Gb actuator configurations
Need a valve sized for your line?Email pipe size, pressure, temperature, medium, flange standard and voltage.
Send Specifications by Email
Why flanged

Flanged construction for secure industrial piping

Compared with compact threaded connections, a flanged electric ball valve is often preferred where the line size, piping standard, maintenance practice or mechanical security calls for a bolted connection.

Large-size coverageSuitable across DN15–DN300 for general industrial automation projects.
Pipeline alignmentBolted flanges support repeatable installation in fixed process piping.
Global standardsANSI, DIN and JIS flange options help match regional and project specifications.
Service accessThe complete valve-actuator assembly can be removed from the line during planned maintenance.
Matching an existing piping standard?Send the flange standard, class / PN rating and face-to-face requirement.
Confirm Flange Compatibility
Selection logic

Flanged vs threaded electric ball valve

Both can automate 2-way shutoff. The connection style should follow pipe size, pressure class, installation method and maintenance practice rather than actuator preference alone.

Flanged electric ball valve
Threaded electric ball valve
الاستخدام النموذجي
Permanent industrial piping, larger diameters, skids and process systems.
Compact equipment piping and smaller line sizes.
الاتصال
Bolted ANSI / DIN / JIS flange interface.
Threaded connection such as NPT / BSP depending on product.
الصيانة
Well suited to planned line isolation and removal in plant piping.
Simple for compact systems, but pipe disassembly practices differ.
Best starting point
Choose when project specs already define flanged piping or larger size coverage.
Choose when compactness and small-bore connection are the priority.
Electric actuator options

Match torque, voltage and control to the shutoff duty

For a standard 2-way ball valve, actuator selection starts with required valve torque and differential pressure, then adds the control mode, power supply, feedback and environmental protection.

On / OffPrimary configuration for automatic isolation and equipment sequencing.
تغذية الارتجاع للموضعSelected limit-switch and passive-contact feedback options.
Fast ActingSelected actuator combinations support shorter opening and closing times.
Manual OverrideHandwheel operation available on selected configurations.
ProtectionIP67 standard on selected models; IP68 options for demanding environments.
Hazardous AreasSelected Ex d II BT4 / CT4 / CT6 Gb configurations.
المشغلStandard time / torqueOptional time / torqueالوزن
FLE-10525s / 50Nm4s / 20Nm; 10s / 30Nm2.2 كجم
FLE-11025s / 100Nm15s / 50Nm5.1 كجم
FLE-11625s / 160Nm15s / 80Nm5.1 كجم
FLE-12025s / 200Nm15s / 100Nm7.5 كجم
FLE-14025s / 400Nm15s / 200Nm7.5 كجم
FLE-16025s / 600Nm15s / 300Nm8.1 كجم
FLE-110050s / 1000Nm25s / 500Nm12.7 كجم
FLE-120050s / 2000Nm25s / 1000Nm12.7 كجم
Need actuator torque matching?Send valve size, line pressure, medium, required speed, voltage and control logic.
Ask About Actuator Sizing
Application environments

Where electric flanged ball valves are commonly used

The FLE-Q-F is positioned as a general industrial isolation valve: simple flow path, secure flange connection and electric quarter-turn automation for systems that need dependable remote shutoff.

Water treatment plant application for electric flanged ball valve
Filtration · RO · DistributionWater & Wastewater

Automatic line isolation around pumps, filters, treatment skids and distribution systems.

Industrial equipment skid piping with electric actuated flange ball valve
OEM · Skids · Process EquipmentIndustrial Equipment

Remote shutoff for packaged systems, pump skids, utility modules and automated machinery.

Oil and gas process piping application for motorized flanged ball valve
Oil · Gas · UtilitiesOil & Gas Service

Automated isolation in compatible utility, transfer and process lines with project-matched materials.

Chemical processing utility line electric 2 way flange ball valve
Process Utilities · Compatible Mediaالمعالجة الكيميائية

General isolation for water, utility fluids and compatible chemical service after material review.

Building equipment or a complete skid?Send the P&ID duty, line size, medium, pressure and electrical standard.
Discuss Your Application
Selection guide

Choose the valve around the piping duty

A standard round-port 2-way ball valve is strongest as an isolation device. If the application needs accurate continuous flow regulation, a V-port or dedicated control valve may be the better choice.

01

Confirm the shutoff function

Use a 2-way valve where the main requirement is to open or isolate one pipeline path.

02

Match pipe and flange

Confirm DN / inch size, ANSI / DIN / JIS standard, pressure class and face requirements.

03

Check media compatibility

Select body, ball, stem and seat materials from the actual medium, concentration and temperature.

04

Define pressure & temperature

Use real operating and design conditions rather than pipe nominal ratings alone.

05

Size actuator torque

Match torque to valve size, pressure differential, seat design and required safety margin.

06

Specify controls

Confirm voltage, on/off logic, feedback, fail position, speed, IP rating and explosion-proof requirement.

Quality assurance

Designed for repeatable industrial automation

Valve testing, actuator protection and project-specific control options support reliable shutoff in water treatment, equipment, chemical and utility systems.

API 598Valve inspection and leakage testing reference.
IP67 / 68Electric actuator protection options for industrial environments.
ISO 5211Standardized quarter-turn actuator mounting interface.
Frequently asked questions

Electric 2 Way Flange Ball Valve FAQs

Questions commonly checked by OEMs, EPC contractors, plant engineers and maintenance teams before ordering a motorized flanged ball valve.

What is an electric 2 way flange ball valve mainly used for?
It is mainly used for automated open-close isolation in a pipeline with one inlet and one outlet. Typical duties include pump isolation, equipment sequencing, water treatment, utility systems, oil and gas service, and compatible industrial process lines.
When should I choose a flanged valve instead of a threaded electric ball valve?
Flanged construction is generally preferred when the piping system already uses ANSI, DIN or JIS flanges, when larger sizes are required, or when the project needs a secure bolted connection and planned maintenance access.
Can a standard 2-way electric ball valve be used for throttling?
Selected modulating actuators can position the valve between open and closed, but a standard round-port ball valve is primarily an isolation valve. For accurate continuous flow regulation, a V-port segmented ball valve or dedicated control valve is usually a better starting point.
Which body material should I choose: WCB, SS304 or SS316?
The correct material depends on the process medium, corrosion risk, operating temperature, pressure and project specification. SS316 is commonly considered where improved corrosion resistance is needed, while WCB is widely used for compatible general industrial service.
Which voltage and control options are available?
Typical power options include DC24V, AC24V, AC110V, AC220V and AC380V depending on actuator model. On/off operation is the primary configuration, with selected feedback, regulating, intelligent, fast-acting and explosion-proof options available.
What information should I send for actuator sizing?
Provide valve size, flange standard, medium, operating pressure and temperature, differential pressure if known, voltage, required opening/closing time, control logic, feedback requirement and environmental protection level.

Need an electric flanged ball valve for your equipment or pipeline?

Send the operating conditions and required control standard. Fleyenda can match the valve body, flange, seat and electric actuator to the project duty.

يستخدم هذا الموقع ملفات تعريف الارتباط لتحسين تجربتك في تصفح الويب.